Brand: Infitek | Category: Medical Equipment

Infitek Fully Automatic Urine Analysis Workstation, UA-S3-120&UA-A3-240 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: UA-S3-120, UA-A3-240. Published details include Sample Volume: Minimum volume:3mL,Aspiration volume:1mL; Aspiration Volume: 1ml. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | UA-S3-120 |
|---|---|
| Test Parameters | Normal RBC, Standing RBC, Dysmorpuic RBC, Normal WBC, WBCC, Pus Cell, Hyaline Cast, Granular Cast,WBC Cast ,Squamous Epithelial Cell,Normal Epithelial Cell, Sperm, Calcium Oxalate Crystal, Bacteria,Yeast, Amorphous Urates, Mucus etc. |
| Test Principle | Flow cell digital imaging technology,medical image fusion technology,artificial intelligence identification technique |
| Channel | Four channels fixed flow counting cell |
| Sample Volume | Minimum volume:3mL,Aspiration volume:1mL |
| Test Speed | 120 samples/hour |
| Aspiration Volume | 1ml |
| Test Sensitivity | 5 cells/μL |
| Accuracy | >95% |
| Repeatability | CV<10% |
| Cross Contamination Rate | <0.05% |
| Data Storage | 200,000 |
| Report Mode | International general quantitative unit; unit /μL&HPF, complete and illustrated report, with urine chemistry test results and urine sediment test results |
| Environment | Temperature:15°C~35°C Optimum temperature: 20°C~25°C Relative humidity:≤75% |
| Electricity | AC220V±10% , 50Hz |
| Dimensions(L*W*H) | 660mm*440mm*570mm |
| N.W./G.W. | 37kg/95kg |
| Shipping Dimension(L*W*H) | 1150*760*770mm |
| Model | UA-A3-240 |
|---|---|
| Test Speed | 240 strips/hour(15 seconds/strip) |
| On Board Sample Capacity | 5 racks of 10 tubes (50 samples) |
| Sample Volume | Minimum volume: 3mL;Aspiration volume:1mL |
| Test Principle | Photoelectric colorimetric method |
| Test Parameters | Urobilinogen(URO), Bilirubin(BIL), Ketone (KET), Blood (BLD), Protein (PRO), Nitrite (NIT), Leukocytes(LEU), Glucose(GLU), Specific Gravity(SG), PH(pH), Ascorbic Acid(VC), Microalbumin(MAL) |
| Data Storage Capacity | 20,000 |
| External Output | RS-232 |
| Electricity | AC 220V, 50Hz |
| Power | 300VA |
| Fuse | 250V 2A |
| Environment | Temperature:15° C ~ 35° C Optimum temperature: 20° C~25° C Relative humidity:≤75% |
| Printer | Thermal printer |
| Dimensions(L*W*H) | 660*625*581mm |
| Net Weight | 65kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Sample Volume: Minimum volume:3mL,Aspiration volume:1mL; Aspiration Volume: 1ml. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
On Board Sample Capacity: 5 racks of 10 tubes (50 samples); Sample Volume: Minimum volume: 3mL. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by Infitek. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.