Oxymat in Bangladesh
Explore 24 unique Oxymat catalogue listings across Scientific & Laboratory Equipment, Nanotechnology. Compare equipment and manufacturer references, then request a quotation for the model, accessories, delivery and support you need.
Plan your purchase: laboratory and industrial oxygen or nitrogen generation
Start with the application and the equipment already in use. These details help the team identify a suitable configuration and an itemised quotation.
Useful details for your quotation
- Gas, purity, flow, pressure and consumption pattern
- Compressed-air quality, receiver and distribution interfaces
- Site utilities, monitoring and maintenance requirements
- Quantities, delivery location and required date
- Installation, training, warranty and service requirements
Confirm the exact model, compatible accessories, documentation, current availability and delivery terms in writing. The catalogue describes equipment options; installation, acceptance and ongoing support are agreed for the proposed configuration.
Discuss Oxymat equipment
Request a quote
Categories
Products
- O200 Nordic: Modular PSA oxygen generator built around two standard size pressure vessels, aimed at sites needing a continuous oxygen supply in a small footprint. Typical duties are aquaculture aeration and wastewater treatment, with Modbus RTU communication and LED operating status.
- O200 Nordic Supreme: Higher capacity version of the O200 modular PSA oxygen range, available in four vessel configurations. It suits aquaculture, wastewater and ozone duties where oxygen demand grows over time, since capacity is added by extending the same frame.
- O60 Nordic: Euro-pallet sized PSA oxygen generator with built-in filters for laboratory and industrial applications such as aquaculture. Confirm the required flow, purity, pressure and feed-air conditions for the selected model. VVON does not supply hospital medical-gas systems.
- O60 Nordic Supreme: Upgraded O60 pallet PSA oxygen generator giving higher output and lower power draw from the same footprint. Oxymat states it uses 40 per cent less zeolite than the standard unit, and it keeps the plug and play filter arrangement.
- Half pallet Nordic oxygen generator: Half euro-pallet PSA oxygen generator for low-flow laboratory and industrial duties, including ozone generation and wastewater-treatment applications. Match the selected configuration to the process gas specification and available utilities.
- Twin-Tower oxygen generator: Skid-mounted, two-column PSA oxygen generator for on-site industrial supply. The configuration can include an oxygen receiver, booster or container installation where specified. VVON offers laboratory and industrial applications; hospital medical-gas supply and medical upgrade kits are outside our scope.
- Compact integrated PSA oxygen generator: All in one cabinet oxygen generator with the air compressor, dryer and oxygen tank built in, so only power and an outlet connection are needed. It suits broodstock and hatchery work in fish farming and other low volume oxygen duties.
- Compact integrated silenced PSA oxygen generator: Compact integrated oxygen generator in a silenced cabinet for laboratory and industrial locations where noise matters. The package includes a compressor, dryer and oxygen tank. Confirm ventilation, power, gas specification and installation requirements before ordering.
- Compact PSA oxygen generator: Low volume PSA oxygen generator in a stainless steel cabinet that mounts on a wall or stands on the floor. A four inch display handles control and performance monitoring, and an external oil-free compressor and integrated oxygen monitor can be added.
- OXYMAT X-series frame-mounted PSA oxygen generator: Frame mounted tonnage PSA oxygen package covering nine models, supplied plug and play with buffer vessels, filters and instrumentation. Oxymat position it as a lower capital cost alternative to a cryogenic air separation unit where footprint is tight.
- Containerized and in-frame oxygen generator installations: Oxygen generation equipment integrated into a container or open frame for industrial sites, including aquaculture, wastewater treatment and mineral processing. Configuration must account for site temperature, altitude, ventilation, power and gas demand. VVON does not offer hospital oxygen installations.
- N200 Nordic: Modular PSA nitrogen generator for duties needing a large continuous supply, widely used on marine vessels for inerting, blanketing and purging. The compact frame also suits retrofit work in oil and gas and food and beverage plant.
- Pallet N60 Nordic: Euro-pallet sized PSA nitrogen generator with built in filters for straightforward installation and later relocation. It is used in food and beverage and oil and gas work, and in power plants for purging and corrosion protection.
- Half pallet Nordic nitrogen generator: Half euro-pallet PSA nitrogen generator, light enough to move easily and small enough for constrained plant rooms. It is aimed at nitrogen supply in manufacturing, food and beverage and electronics work.
- Twin-Tower nitrogen generator: Skid mounted two column PSA nitrogen plant with four decades of service history, covering everything from small flows to tonnage duties. A nitrogen booster and cylinder filling station can be added, and the plant can be container or frame built.
- Membrane nitrogen generator NM series: Membrane nitrogen generator in single- and double-membrane configurations for applications such as marine inerting. Compare flow at the required nitrogen purity and pressure. Verify dimensions and the exact classification approvals needed for the proposed installation.
- Compact integrated PSA nitrogen generator: All in one cabinet nitrogen generator with the oil-free compressor, dryer and nitrogen tank built in. It covers low volume duties such as wineries, packaging and fire protection, and mounts on a wall or on the floor.
- Compact integrated silenced PSA nitrogen generator: Compact integrated nitrogen generator housed in a silenced cabinet for quiet operation. The compressor, dryer and nitrogen tank are built in, so the unit only needs power and an outlet connection to run.
- Compact PSA nitrogen generator: Low volume PSA nitrogen generator in a stainless steel cabinet, mounted on a wall or floor with a four inch display for control and monitoring. An external oil-free compressor can be supplied where one is not already available.
- OXYMAT X-series frame-mounted PSA nitrogen generator: Frame mounted tonnage PSA nitrogen package covering nine models, supplied plug and play with buffer vessels, filters and instrumentation. Oxymat report well over one hundred installations of this design worldwide.
- Nitrogen purifier NH 20-400: Downstream purifier for reducing residual oxygen in PSA nitrogen through a controlled hydrogen-assisted reaction and subsequent drying. Confirm compatibility with the generator, required impurity limits and utility and safety requirements with Oxymat before specifying a combined system.
- Containerized and in-frame nitrogen generator installations: Nitrogen plant built into a container or open frame for rigs, refineries and remote sites. Oxymat supply ATEX rated units and documentation to nuclear power plant level, with installations running from Saudi Arabia to Greenland and the Himalayas.
- Nitrogen booster and filling station: Oxymat list a nitrogen booster and filling station as an optional item on their twin-tower PSA nitrogen generator page. No pressure rating, purity or flow figure is published for the booster and filling station itself. The nitrogen generator it belongs to is listed at 1 to 5550 Nm3/h at 99.9999% purity.
- Oxygen booster and filling station: The oxygen booster and filling station is one of the optional parts of Oxymat's twin-tower PSA oxygen system, which otherwise consists of a compressed air system, a PSA skid and an oxygen receiver, with a container or frame-built solution also optional. No pressure rating, purity or flow figure is published for the booster and filling station itself. The oxygen generator it belongs to is listed at 2 to 473 Nm3/h at 95% purity.
Oxymat equipment: purchase questions
Which Oxymat equipment can I find here?
This VVON catalogue covers laboratory and industrial oxygen or nitrogen generation. Use the category filter or search a product or model, then open the product page for its description and manufacturer reference. Catalogue entries do not establish current local stock or every product in the manufacturer's worldwide range.
What details help prepare a Oxymat quotation?
Include: Gas, purity, flow, pressure and consumption pattern; Compressed-air quality, receiver and distribution interfaces; Site utilities, monitoring and maintenance requirements. Add the quantities, delivery location and required date. You can add several products to one enquiry list or request help selecting the configuration.
What affects Oxymat equipment pricing in Bangladesh?
Specify gas, required purity, flow and pressure, then separate generator, compressed-air treatment, storage, monitoring and installation. VVON's scope here is industrial and laboratory applications. Request a dated, itemised quotation stating currency, taxes, delivery, warranty and service responsibilities. A catalogue listing is not a current price or local-stock commitment.
Buying guides for Oxymat equipment
Compare industrial and laboratory gas-generation scope
Define the gas, purity, flow and delivery pressure together. VVON’s advertised scope here is laboratory and industrial generation, not hospital medical-gas pipelines or oxygen-supply services.
Nitrogen: N200 Nordic
Compare the required nitrogen duty and proposed generator configuration.
Confirm in the offer: Confirm the guaranteed purity/flow operating point, feed air and downstream equipment.
Explore Nitrogen: N200 NordicOxygen: O200 Nordic
Discuss the industrial or laboratory application and its oxygen requirements.
Confirm in the offer: Identify application suitability, utilities, outlet conditions and safety responsibilities.
Explore Oxygen: O200 NordicGenerator requirements
Prepare the operating profile and complete installation boundary.
Confirm in the offer: Separate compressor, treatment, receiver, controls, installation and service in the proposal.
Explore Generator requirementsPrepare a comparable quotation
- Gas, required purity, flow/pressure and duty profile
- Available compressed air, power, ventilation and footprint
- Supporting equipment, commissioning and maintenance scope
Reference information Discuss your shortlist