Imaging & QA Software in Bangladesh
SCINTRON clinical processing modules and quality assurance analysis software for nuclear medicine and radiology.
28 products from 3 manufacturers: MiE GmbH, Spectrum Dynamics Medical, Leeds Test Objects.
Products
- Bone - 3 Phase Scintigraphy — MiE GmbH: A SCINTRON planar processing program that compares a suspected area with a normal one across the flow, blood pool and skeletal phases of a three phase bone study. Regions of interest are placed for each image, and numerical and graphical results are shown with sacroiliac joint quantification.
- Bone - SPECT — MiE GmbH: A SCINTRON SPECT processing program for skeletal studies. It uses DROSEM iterative reconstruction for half time imaging or dose reduction, offers a range of slice displays including maximum intensity projection, and includes a 3D toolbox for post processing.
- Bone - Whole Body Scan — MiE GmbH: A SCINTRON planar processing program for whole body bone scans. Up to four projections can be viewed, including a dual intensity display, with cutting and masking tools and a zoom function for up to three chosen cut outs. Deconvolution denoising is available as an option.
- Bone - Wholebody SPECT — MiE GmbH: A SCINTRON processing program that stitches SPECT acquisitions from several bed positions, normalises them and presents them as one study. Up to five bed positions can be used, each remains readable on its own, and DROSEM 3D OSEM reconstruction keeps acquisition times short.
- Lung - Quantification — MiE GmbH: A SCINTRON planar processing program that compares right and left lung perfusion or ventilation. From ventral and dorsal studies it places a chosen number of regions of interest symmetrically on each lung and calculates relative density. Free hand regions can also be selected.
- Lung - SPECT — MiE GmbH: A SCINTRON SPECT processing program for lung studies. It places ventilation and perfusion data sets side by side for direct comparison and calculates the ventilation to perfusion mismatch, so the two acquisitions can be read together rather than one after the other.
- Brain SPECT — MiE GmbH: A SCINTRON SPECT processing package for neurological studies. It covers DaTSCAN evaluation of presynaptic dopamine transporter binding, IBZM processing of postsynaptic D2 receptor status, and brain perfusion work with left and right hemisphere ratios from segmented regions of interest.
- Myocard SPECT — MiE GmbH: A SCINTRON cardiac SPECT package that builds the bullseye polar map of activity in the left ventricle from stress or rest studies. Gated and non gated data can be processed, ejection fraction, wall motion and wall thickening are calculated, and results compare against a normal database.
- Thyroid - Radioiodine Test — MiE GmbH: A SCINTRON planar program that calculates a recommended therapy activity from the uptake of an I-131 test capsule measured on a gamma camera. Three methods are implemented, based on effective half life, on a single late measurement, or on a 24 hour measurement with default half lives.
- Thyroid - Scintigraphy and Uptake Calculation — MiE GmbH: A SCINTRON planar program for thyroid scintigraphy and uptake. Syringe activity can be measured on the camera or a dose calibrator and organised by number, anatomical markers are set after acquisition, and individual therapy doses and suppression tests can be calculated.
- Kidney - TER, GFR and ERPF calculation — MiE GmbH: A SCINTRON renography package covering MAG3, DTPA and OIH studies. Start time is recognised automatically so one person can inject and acquire, the measurement protocol with syringe, serum sample and calibration data is supported, and age and gender dependent normal values are applied.
- Hepatobiliary Scintigraphy and Gastric Emptying — MiE GmbH: The HeparX program visualises and archives hepatocellular function and calculates the gallbladder ejection fraction from pre and post sincalide data using regions of interest over the gallbladder and adjacent liver. Dynamic gastric emptying studies and curve parameters are also processed.
- Kidney - DMSA Scintigraphy — MiE GmbH: A SCINTRON planar program that shows tracer distribution in the kidneys and calculates the left to right relation. It outlines the existence, position, size and shape of each kidney and determines differential renal function with background and depth correction.
- ECT Program — MiE GmbH: The core SPECT reconstruction program in SCINTRON. It handles gated and non gated studies, offers filtered backprojection alongside HOSP, OSEM and DROSEM iterative methods, corrects motion during reconstruction, and provides rotation, 3D zoom, sinogram and cine tools.
- 3D Acquisition with CASCADE Scatter Correction — MiE GmbH: The 3D PET acquisition mode in the SCINTRON PET software, used with CASCADE scatter correction. MiE state that it allows cardiac PET doses between 9 mCi for N-13 and 30 mCi for Rb-82 without sacrificing image quality, which lowers exposure for patient and technologist.
- Cardiac Matching Application — MiE GmbH: A SCINTRON PET processing tool that corrects registration between transmission and emission studies after acquisition. It removes the misalignment caused by patient movement, which would otherwise produce false reconstruction and reading of cardiac studies.
- CFR via List-Mode Acquisition — MiE GmbH: A list mode acquisition protocol that SCINTRON brings to the ECAT family of PET scanners. It lets the user create several data sets from a single acquisition, for example the data needed for coronary flow reserve, without having to repeat the study.
- Quantification Integration — MiE GmbH: An interface in the SCINTRON PET software for the common cardiac quantification packages, including Invia 4DM and Cedars Sinai QPET. Reconstructed studies pass straight into the reading software the department already uses, rather than being exported by hand.
- FUSION Software — MiE GmbH: Multi modality image fusion for SPECT, PET and CT studies from hybrid or standalone systems. The registration methods work automatically and handle rigid and non linear patient movement, and Hounsfield unit windowing with selectable colour scales controls the display.
- TruCorr Attenuation Correction — Spectrum Dynamics Medical: Deep learning attenuation correction for myocardial perfusion imaging on the D-SPECT. A convolutional neural network works from the patient's own SPECT emission data in a single acquisition, so no CT or Gd-153 transmission scan is needed to produce a corrected data set.
- Veritas.AI Noise Reduction — Spectrum Dynamics Medical: Deep learning noise reduction for the VERITON-CT digital SPECT/CT. It reduces image noise without giving up spatial resolution or quantitative accuracy, which supports faster acquisitions and lower administered activity. Spectrum Dynamics state that it holds FDA 510(k) clearance.
- TruClear.AI Noise Reduction — Spectrum Dynamics Medical: Deep learning noise reduction for myocardial perfusion imaging on the D-SPECT. It reduces statistical noise in low count acquisitions and returns clear perfusion and gated reconstructions, so image quality holds up when scan time or administered activity is cut back.
- TruFlow Dynamic Imaging — Spectrum Dynamics Medical: Dynamic SPECT software for the D-SPECT, including myocardial blood flow assessment. It uses list mode acquisition with flexible reconstruction to support traditional and fast dynamic protocols, and passes results to established quantitative analysis tools.
- Cardiac First-Pass — MiE GmbH: A SCINTRON planar program for first pass studies of the heart, acquired while a bolus of high activity is still inside one ventricle. Working from high speed dynamic frames it avoids the background and overlap problems of multi gated studies, and computes ejection fraction, heart rate and cycle length.
- Deconvolution — MiE GmbH: A SCINTRON processing option that improves the signal to noise ratio of planar studies using standardised parameters, so contours are displayed more sharply. MiE make it available for the Bone, WholeBody and Multidisplay programs, and the result can be read against the raw data side by side.
- DYNAX - Renal Scintigraphy — MiE GmbH: A SCINTRON program for quantitative analysis of dynamic studies. For renal work it determines side ratios, calculates counts and region sizes, and shows renal function as curves. The same program handles salivary gland studies, giving uptake before irritation and the excretion fraction.
- Analysis of Suppression — MiE GmbH: A SCINTRON program that compares a thyroid uptake study acquired before suppression with one acquired after it. The same regions are applied to both studies, and the ratio between the two is calculated automatically as a percentage alongside the uptake and area figures for each acquisition.
- AutoPIA — Leeds Test Objects: Automatic Phantom Image Analysis software that recognises and analyses test images of Leeds Test Objects phantoms. It calculates reproducible quality indices, stores the results and plots control charts with baseline and threshold values so quality trends and abnormal conditions are visible.