Hot Lab Shielding & L-Blocks in Bangladesh
Nuclear Shields L-block workstations and hot lab shielding for radiopharmacy dispensing.
33 products from 2 manufacturers: Nuclear Shields, MiE GmbH.
Products
- Corner Tabletop Shield - 3 mm — Nuclear Shields: A benchtop lead shield that stands between the operator and the activity on the bench, sized to sit on an existing worktop without any building work. Shielding is 3 mm of lead, outside dimensions 350 x 450 x 350 mm (w x d x h).
- Cyclotron Workstation - 50 mm — Nuclear Shields: A heavily shielded workstation for cyclotron produced radionuclides, giving a large shielded working area for target handling and processing. Shielding is 50 mm of lead, inside dimensions 880 x 531 mm (working area).
- Dose Drawing Station — Nuclear Shields: A dose drawing station that holds the vial shield and the syringe in a fixed shielded position while the dose is drawn, so the hands stay out of the direct beam. It is used in the radiopharmacy at the point where doses are drawn from a bulk vial into individual syringes.
- Mobile PET Workstation - 50 mm — Nuclear Shields: A mobile PET workstation with a movable lead screen and a shielded work surface, for preparing and dispensing high energy PET radiopharmaceuticals. Shielding is 55 mm movable screen & 20 mm work surface of lead, inside dimensions 1110 x 705 mm (working area).
- QC L-Block Station - 50 mm — Nuclear Shields: A floor standing L-block station for quality control and dose preparation work in the hot lab, with a lead shielded working area and a lead glass viewing window. Shielding is 50 mm of lead, inside dimensions 880 x 530 x 255 mm (working area).
- QC L-Block Station (SPECT) — Nuclear Shields: A floor standing L-block station for quality control and dose preparation work in the hot lab, with a lead shielded working area and a lead glass viewing window. Shielding is 5 mm of lead, inside dimensions 953 x 603 x 255 mm (working area).
- QC L-Block Station with waste compartment - 50 mm — Nuclear Shields: A floor standing L-block station for quality control and dose preparation work in the hot lab, with a lead shielded working area and a lead glass viewing window. Shielding is 50 mm of lead, inside dimensions 880 x 530 x 255 mm (working area).
- Shielded synthesis workstation — Nuclear Shields: A shielded synthesis workstation for radiochemistry, with heavy lead shielding on the sides and front and a shielded workbench. Shielding is 50 mm in sides & front / 10 mm in back & workbench of lead, inside dimensions 1485 x 485 x 620 mm (working area).
- Tabletop L-Block Shield - 20 mm — Nuclear Shields: A benchtop L-block shield for handling gamma emitting radiopharmaceuticals, with a lead glass window that keeps the working area in view while the body of the shield stands between the operator and the dose. Shielding is 20 mm of lead, outside dimensions 422 x 505 x 580 mm (w x d x h).
- Tabletop L-Block Shield - 30 mm — Nuclear Shields: A benchtop L-block shield for handling gamma emitting radiopharmaceuticals, with a lead glass window that keeps the working area in view while the body of the shield stands between the operator and the dose. Shielding is 30 mm of lead, outside dimensions 426 x 516 x 604 mm (w x d x h).
- Tabletop L-block Shield - 5 mm — Nuclear Shields: A benchtop L-block shield for handling gamma emitting radiopharmaceuticals, with a lead glass window that keeps the working area in view while the body of the shield stands between the operator and the dose. Shielding is 5 mm lead & 5 mm aluminum of aluminum, lead, outside dimensions 416 x 486 x 549 mm (w x d x h).
- Tabletop L-Block Shield - 50 mm — Nuclear Shields: A benchtop L-block shield for handling gamma emitting radiopharmaceuticals, with a lead glass window that keeps the working area in view while the body of the shield stands between the operator and the dose. Shielding is 50 mm of lead, outside dimensions 425 x 550 x 590 mm (w x d x h).
- Tabletop L-Block Shield -12.5 mm — Nuclear Shields: A benchtop L-block shield for handling gamma emitting radiopharmaceuticals, with a lead glass window that keeps the working area in view while the body of the shield stands between the operator and the dose. Shielding is 12.5 mm of lead, outside dimensions 422 x 484 x 559 mm (w x d x h).
- Tabletop Shield - 12 mm — Nuclear Shields: A benchtop lead shield that stands between the operator and the activity on the bench, sized to sit on an existing worktop without any building work. Shielding is 12 mm of lead, outside dimensions 320 x 250 x 520 mm (w x d x h).
- Tabletop Shielded Workstation - 5 mm — Nuclear Shields: A benchtop lead shield that stands between the operator and the activity on the bench, sized to sit on an existing worktop without any building work. Shielding is 5 mm of lead, inside dimensions 565 x 362 x 293 mm.
- Tabletop Shielded Workstation - 8 mm lead 10 mm aluminum — Nuclear Shields: A benchtop lead shield that stands between the operator and the activity on the bench, sized to sit on an existing worktop without any building work. Shielding is 8 mm lead & 5 mm aluminum of aluminum, lead, inside dimensions 565 x 362 x 293 mm.
- Lead Castle - Sliding Door (LC310-412-100SD) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- Lead Castle - Sliding Door (LC310-412-100SD-2C) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. Shielding is 100 mm of lead, inside dimensions 302 x 403 mm (diameter x height).
- Lead Castle - Sliding Door (LC315-416-100SD) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- Lead Castle - Sliding Doors — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- Lead Castle - Sliding Top Door — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. Shielding is 150 mm of lead, inside dimensions 293 x 394 mm (diameter x height).
- Lead Castle - top door (LC150-350-100T) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. Shielding is 100 mm of lead, inside dimensions 150 x 400 mm (diameter x height).
- Lead Castle - top door (LC197-600-30T) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. Shielding is 30 mm of lead, inside dimensions 196 x 600 mm (diameter x height).
- Lead Castle - top door (LC150-250-100T) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- Lead Castle - top door (LC280-400-100T) — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- Lead Castle - Top/Front door — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. Shielding is 100 mm of lead, inside dimensions 280 x 400 mm (diameter x height).
- Square Lead Castle - Sliding Door — Nuclear Shields: A lead castle that encloses a source or a detector on all sides, with an access door so the contents can be reached without dismantling the shielding. It is used around gamma sources, germanium detectors and low background counting equipment, where the shielding has to be close fitting on every side.
- HFC Shielding - 12,5 mm (LP-E0031751) — Nuclear Shields: Built in stainless steel, this unit shields hand and foot monitors used in radiation controlled environments. The integrated 12,5 mm lead shielding reduces the influence of ambient radiation on the measurement, so radioactive contamination on hands and feet is detected more reliably. Nuclear Shields describe the construction as robust and practical to use, suited to locations where accurate contamination monitoring and radiation safety are essential.
- Lead Castle Ultra Low Background no. 1 (LCU430-200T-D2) — Nuclear Shields: An ultra low background lead castle catalogued by Nuclear Shields as LCU430-200T-D2. Its inside dimensions are a diameter of 430 mm by 200 mm high. The shield is built from 9 cm LBL and 1 cm ULBL, and a copper liner and frame are included.
- Lead Castle - top door (LC152-566-50T) — Nuclear Shields: A top door lead castle from Nuclear Shields, catalogued as LC152-566-50T. Inside dimensions are 152 x 566 mm. The unit is made according to drawing #E0003542.
- Lead Castle - Sliding Door (LC150-200-100SD) — Nuclear Shields: A sliding door lead castle from Nuclear Shields, catalogued as LC150-200-100SD. Inside dimensions are 150 x 200 mm, quoted including a 2 mm copper inner liner.
- Lead Castle — MiE GmbH: A lead castle from MiE, supplied including a lead glass window. Different sizes and shieldings are available on request, with 50 mm and 18 mm given as examples. MiE publish it within the accessories range for their own nuclear medicine systems.
- Mobile Radiation Shield with Lead Glass — MiE GmbH: A mobile radiation protection screen from MiE fitted with a lead glass viewing panel. Overall dimensions are 77 cm x 161 cm x 75 cm (30.3 in x 63.3 in x 29.5 in) width by height by depth, and the lead glass panel measures 68 cm x 68 cm (26.8 in x 26.8 in). Lead equivalent is 1,5 mm Pb. Other dimensions are available on request.
All Nuclear Medicine & Imaging categories