Brand: GEMMY Industrial | Category: Medical Equipment
The larger analogue dry bath, 3.5 kg with a 450 W heater reaching 105 degrees C, with uniformity at 37 degrees C quoted at 0.5 degrees C under PID control. Setting is analogue with a thermometer readout and an over heat alarm. It covers the same bench work as the rest of the DB range: incubating DNA specimens, blood bank cross matching and screening, melted agar, enzyme assays, digestions, milk residue tests, serology, haematology, pathology and biochemistry. Heating blocks are interchangeable for test tubes, cuvettes and microcentrifuge tubes, each with a thermometer well, and a solid block converts the unit to a hot plate.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about GEMMY Industrial equipment requirements in Bangladesh.
Phone: +880 1711-738207 | Email: info@vvon.com.bd
The digital dry bath in the range, with digital setting, an LED digital readout and a digital 99 hour timer, which the analogue DB-005 and DB-006 do not carry. The 450 W heater runs to 99 degrees C with uniformity at 37 degrees C quoted at 0.5 degrees C under PID control, and an over heat alarm is fitted. Net weight is 5.5 kg. The same interchangeable heating blocks accept test tubes, cuvettes and microcentrifuge tubes, each with a well for a removable thermometer, and a solid block turns the unit into a hot plate.
The compact analogue dry bath in GEMMY's range, weighing 2.5 kg with a 200 W heater and a maximum of 105 degrees C, holding uniformity at 37 degrees C to 0.3 degrees C under PID control. Temperature is set on an analogue control and read from a thermometer, with an over heat alarm fitted. Applications listed include incubating DNA specimens, cross matching and screening in the blood bank, incubating melted agar, enzyme assays, digestions and milk residue tests, as well as serology, haematology, pathology and biochemistry work. Interchangeable heating blocks accept test tubes, cuvettes and microcentrifuge tubes, each with a well for a removable thermometer, and a solid block with no holes turns the unit into a hot plate.
A laboratory incubator offered in six capacities from 34 to 150 litres, working from ambient plus 5 degrees C to 75 degrees C, in either an analogue or a digital build. The analogue version uses ON/OFF control with a mercury thermometer on the top of the cabinet and natural gravity convection, giving uniformity of +/-5.0 degrees C and stability of +/-3.0 degrees C at 37 degrees C. The digital version uses microprocessor PID control with forced convection, tightening uniformity to +/-3.0 degrees C and stability to +/-1.0 degrees C at 37 degrees C, and cuts out at 4 degrees C above the set point rather than at 80 degrees C. On the digital model the mechanical 180 minute timer starts only once the set temperature has stabilised, shows END when the cycle finishes, and stores the temperature and elapsed time if the door is opened mid run.