Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE High Performance Liquid Chromatography System BK-1800HPLC is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-1800HPLC(Type I); Isocratic manual system, BK-1800HPLC; (Type II); Binary gradient manual system, BK-1800HPLC(Type III); Binary gradient manual system with PDA, BK-1800HPLC; (Type IV); Quaternary gradient manual system, BK-1800HPLC; (Type V) Quaternary gradient manual system with PDA. Published details include Flow Cell Volume: Volume 10.0μl; adopts cone structure /With optional temperature control module; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Liquid Infusion System | Type I Reciprocating infusion pumps |
|---|---|
| Flow Rate Range | 62MPa 0.001-10ml/min, 0.001ml/min increment |
| Max Output Pressure | 62MPa(corresponding 9000psi) |
| Flow Precision | ≤0.06%RSD |
| Flow Accuracy | ≤±0.3% |
| Compression Compensation | Automatic, continuous, selectable solvent type |
| Post-column Cleaning | Automatic post-column cleaning function, which can control the cleaning flow rate |
| Extended Application | Record the number of times the plunger rod seal is used |
| Liquid Infusion System | Type I Reciprocating infusion pumps |
|---|---|
| Flow Rate Range | 62MPa 0.001-10 ml/min, 0.001ml/min increment |
| Max Output Pressure | 62MPa(corresponding 9000psi) |
| Flow Precision | ≤0.06%RSD |
| Flow Accuracy | ≤±0.3% |
| Compression Compensation | Automatic, continuous, selectable solvent type |
| Post-column Cleaning | Automatic post-column cleaning function, which can control the cleaning flow rate |
| Gradient Setting Range | 0~100% |
| Extended Application | Record the number of times the plunger rod seal is used |
| Liquid Infusion System | Linear motor digital-driven pump |
|---|---|
| Flow Rate Range | 0.001-10.0ml/min in steps of 0.001 |
| Max Output Pressure | 70MPa (corresponding 10150psi) |
| Flow Precision | ≤0.06%RSD |
| Flow Accuracy | ≤±0.3% |
| Compression Compensation | Automatic, continuous, selectable solvent type |
| Post-column Cleaning | Automatic post-column cleaning function, which can control the cleaning flow rate |
| Gradient Setting Range | 0~100% |
| Online Degassing | Degassing channel systec AF |
| Degassing Chamber | 480μl |
| Extended Application | Record the number of times the plunger rod seal is used |
| Flow Cell Volume | Volume 10.0μl; adopts cone structure /With optional temperature control module |
|---|---|
| Light Source | Deuterium lamp |
| Wavelength Range | 190~700nm |
| Spectrum Bandwidth | 8nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Precision | Below 0.1nm |
| Noise | ≤0.25*10⁻⁵AU (static)/±1*10⁻⁵AU (dynamic, under specified test conditions) |
| Drift | ≤0.4*10^(-4)AU/h (static)/±2*10^(-4)AU/h (dynamic, under specified test conditions) |
| Sampling Frequency | Up to 100Hz |
| Number of Diode Arrays | 512 |
|---|---|
| Light Source | Deuterium lamp + tungsten lamp |
| Wavelength Range | 190~820nm |
| Wavelength Precision | ±0.5nm |
| Wavelength Accuracy | ±1nm |
| Noise | ±5*10^( -6)AU, under specified conditions |
| Drift | 1*10^(-4)AU/h, under specified conditions |
| Sampling Frequency | Up to 100Hz |
| Spectral Bandwidth | 10nm |
| Flow Cell Path Length | 5mm(10mm is optional); Up to 8 channels of digital signal output |
| Model | BK-1800HPLC(Type I); Isocratic manual system | BK-1800HPLC; (Type II); Binary gradient manual system | BK-1800HPLC(Type III); Binary gradient manual system with PDA | BK-1800HPLC; (Type IV); Quaternary gradient manual system | BK-1800HPLC; (Type V) Quaternary gradient manual system with PDA |
|---|---|---|---|---|---|
| Diode Array Detector | / | / | Yes | / | Yes |
| Pump | EX1800 HPC*1 | EX1800 BPC*1 | EX1800 BPC*1 | EX1800 QLPC*1 | EX1800 QLPC*1 |
| Solvent Tray | EX1800 TR*1 | EX1800 TR*1 | EX1800 TR*1 | EX1800 TR*1 | EX1800 TR*1 |
| UV Detector | EX1800 UV*1 | EX1800 UV*1 | / | EX1800 UV*1 | / |
| Manual Sampler 7725i | Yes | Yes | Yes | Yes | Yes |
| C18 5μm ID4.6*250mm | Yes | Yes | Yes | Yes | Yes |
| Workstation EX-Clarity C50 | Yes | Yes | / | Yes | / |
| Power Supply | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz |
| Optional Accessory | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, column oven: EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven auto-sampler: EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, column oven: EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven auto-sampler: EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, column oven: EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven auto-sampler: EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, column oven: EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven auto-sampler: EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, column oven: EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven auto-sampler: EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function |
| Package Size (W*D*H) | 720*580*410mm*3 | 720*580*410mm*3 | 720*580*410mm*3 | 720*580*410mm*3 | 720*580*410mm*3 |
| Gross Weight | 22kg; 20kg; 14kg | 31kg; 20kg; 14kg | 31kg; 23kg; 14kg | 23kg; 20kg; 14kg | 23kg; 23kg; 14kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Flow Cell Volume: 1.0μl; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.
Flow Cell Volume: 8.0μl; Wavelength Range: 190~680nm. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.