Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE High Performance Liquid Chromatography System BK-100HPLC is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-100HPLC; (Type I); Isocratic manual system, BK-100HPLC; (Type II); Gradient manual system, BK-100HPLC; (Type III); Isocratic manual system, BK-100HPLC; (Type IV); Gradient manual system, BK-100HPLC; (Type V) Binary gradient manual system with PDA. Published details include Flow Cell Volume: 8.0μl; Wavelength Range: 190~680nm. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Liquid Infusion System | Dual-piston reciprocating parallel pump, equipped with a binary high-pressure mixer |
|---|---|
| Flow Rate Range | 0.001~10ml/min |
| Max Output Pressure | 42MPa |
| Flow Accuracy | ≤±1% |
| Flow Precision | RSD<0.07% |
| Qualitative Repeatability | RSD6≤0.1%(naphthalene/methanol standards) |
| Quantitative Repeatability | RSD6≤0.3%(naphthalene/methanol standards) |
| Pressure Fluctuation | 0.1MPa |
| Power Supply | AC220/110V, 50/60Hz |
| Flow Cell Volume | 8.0μl |
|---|---|
| Light Source | D2 lamp |
| Wavelength Range | 190~680nm |
| Spectrum Bandwidth | 8nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Precision | Below 0.1nm |
| Noise | ≤0.25x10⁻⁵AU(static)/±1x10⁻⁵AU(dynamic, under given conditions) |
| Drift | ≤0.4x10⁻³AU/h(static)/≤2x10⁻³AU/h(dynamic, under given conditions) |
| Minimum Detectable Concentration | 3x10⁻⁹g/ml(naphthalene/methanol solution) |
| Wavelength Range | 200~900nm(200~600*), Above 600nm just for W lamp |
|---|---|
| Arrays | 512 |
| Spectrum Bandwidth | 10nm |
| Light Source | D2 lamp+W lamp |
| Noise | ±5*10⁻⁵AU |
| Sample Rate | Max100Hz |
| Interface | LAN, USB, R232 |
| Sample Loading | Standard tray (1) 2ml*54 vials(default standard configuration); Expanded tray (2) 10ml*15 vials (3) 4ml*35 vials; Each side could be set with one of the tray types and the tray in one side could be different from the other side; the system could automatically identify the tray type; maximum 108 vials are available(2ml vial) |
|---|---|
| Vial Height | H≤52mm(including septa and cap-mat) |
| Metering Pump Volume | 200μl(precision: 0.1μl) |
| Injection Mode | Full loop injection Partial loop injection No waste injection |
| Automatic Protection | Vial-missing alarm, sample needle fault alarm, pipeline jammed alarm, and leakage alarm |
| Power Supply | AC115~230V, 50/60Hz |
| System Test Quantitative Repeatability | Full loop injection: RSD6≤0.3%; Partial loop injection: RSD6≤0.5%(injection volume ≥ 10μl) No waste injection: RSD6≤1.0%(injection volume ≥ 10μl) |
| Memory Effect | ≤0.005%(designated washing procedure) |
| Maximum Pressure | 40Mpa(conventional) 69Mpa(ultra-high performance system) |
| Model | BK-100HPLC; (Type I); Isocratic manual system | BK-100HPLC; (Type II); Gradient manual system | BK-100HPLC; (Type III); Isocratic manual system | BK-100HPLC; (Type IV); Gradient manual system | BK-100HPLC; (Type V) Binary gradient manual system with PDA |
|---|---|---|---|---|---|
| Software With Audit Trail | / | / | Yes ; | Yes | Yes |
| Diode Array Detector | / | / | / | / | Yes |
| High-pressure Constant Flow Pump | LC-100 HP*1 | LC-100 HP*2 | LC-100 HP*1 | LC-100 HP*2 | LC-100 HP*2 |
| UV Detector; LC-100 UV | Yes | Yes | Yes | Yes | / |
| Diode Array Detector (With English Workstation) | / | / | / | / | LC-100 PDA*1 |
| Workstation LC-100 WS | Yes | Yes | / | / | / |
| Workstation EX-Clarity C50 | / | / | Yes | Yes | / |
| Manual Sampler 7725i | Yes | Yes | Yes | Yes | Yes |
| C18 5μm ID4.6*250mm | Yes | Yes | Yes | Yes | Yes |
| High-precision Mixer EX1600 MX3 | / | Yes | / | Yes | Yes |
| Power Supply | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz |
| Optional Accessory | UV detector, RI detector, PDA detector, ELSD detector, FLD100 detector, column, LC-CO 100 standard column oven, ARCUS 5 auto-sampler | UV detector, RI detector, PDA detector, ELSD detector, FLD100 detector, column, LC-CO 100 standard column oven, ARCUS 5 auto-sampler | UV detector, RI detector, PDA detector, ELSD detector, FLD100 detector, column, LC-CO 100 standard column oven, ARCUS 5 auto-sampler | UV detector, RI detector, PDA detector, ELSD detector, FLD100 detector, column, LC-CO 100 standard column oven, ARCUS 5 auto-sampler | UV detector, RI detector, PDA detector, ELSD detector, FLD100 detector, column, LC-CO 100 standard column oven, ARCUS 5 auto-sampler |
| Package Size (W*D*H) | 450*620*350mm*2 | 450*620*350mm*3 | 450*620*350mm*2 | 450*620*350mm*3 | 450*620*350mm*2 660*560*500mm*1 |
| Gross Weight | 19kg; 15kg | 19kg; 19kg; 15kg | 19kg; 15kg | 19kg; 19kg; 15kg | 19kg; 19kg; 18kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Flow Cell Volume: Volume 10.0μl; adopts cone structure /With optional temperature control module; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.
Flow Cell Volume: 1.0μl; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.