Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE BK-1800UHPLC Ultra-high Performance Liquid Chromatography System is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-1800UHPLC(Type I) Binary gradient automatic system with UV, BK-1800UHPLC(Type II) Binary gradient automatic system with PDA. Published details include Flow Cell Volume: 1.0μl; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Liquid Infusion System | Digital linear motor driven serial pump |
|---|---|
| Flow Rate Range | 0.001~5.000ml/min, 0.001ml/min increment |
| Max Output Pressure | 120MPa |
| Flow Accuracy | ≤0.06%RSD |
| Flow Precision | ≤±0.3% |
| Compression Compensation | Automatic, continuous, selectable solvent type |
| Post-column Cleaning | Automatic post-column cleaning function, which can control the cleaning flow rate |
| Gradient Setting Range | 0~100% |
| Extended Application | Record the number of times the plunger rod seal is used |
| Flow Cell Volume | 1.0μl |
|---|---|
| Light Source | Deuterium lamp |
| Wavelength Range | 190~700nm |
| Spectrum Bandwidth | 4nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Precision | 0.1nm |
| Noise | ≤0.2*10⁻⁵AU (Air cell, 254nm, 20°C) |
| Drift | ≤0.4*10^(-4)AU/h (Air cell, 254nm, 20°C) |
| Sampling Frequency | 100Hz |
| Number of Diode Arrays | 512 |
|---|---|
| Light Source | Deuterium lamp + tungsten lamp |
| Wavelength Range | 200~800nm |
| Wavelength Precision | ±0.5nm |
| Wavelength Accuracy | ±0.1nm |
| Noise | ±5*10^( -6)AU, under specified conditions |
| Drift | 1*10^(-4)AU/h, under specified conditions |
| Sampling Frequency | 100Hz |
| Spectral Bandwidth | 10nm |
| Model | BK-1800UHPLC(Type I) Binary gradient automatic system with UV | BK-1800UHPLC(Type II) Binary gradient automatic system with PDA |
|---|---|---|
| Diode Array Detector | / | Yes |
| UV Detector | EX1800 SUV*1 | / |
| Pump | EX1800 ULBP*1 | EX1800 ULBP*1 |
| Solvent Manager | EX1800SO SD4*1 | EX1800SO SD4*1 |
| Auto-sampler | EX1800 UAS*1, pressure resistant 120MPa, max 108pcs 2mL vials, quadruple protection device | EX1800 UAS*1, pressure resistant 120MPa, max 108pcs 2mL vials, quadruple protection device |
| Column Oven | EX1800 CO*1, temperature range: RT+5~80℃ | EX1800 CO*1, temperature range: RT+5~80℃ |
| Pronaos EP-C18, 5μm, 4.6*250mm | Yes | Yes |
| Workstation EX-Clarity C50 | Yes | / |
| Power Supply | AC220/110V, 50/60Hz | AC220/110V, 50/60Hz |
| Optional Accessory | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, EX1800 CO II refrigerated column oven: temperature range: RT-15~80℃ Auto-sampler: EX1800 UAS II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device EX1800 UAS C II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device, with cooling function | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, EX1800 CO II refrigerated column oven: temperature range: RT-15~80℃ Auto-sampler: EX1800 UAS II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device EX1800 UAS C II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device, with cooling function |
| Package Size (W*D*H) | 720*580*410mm*4; 720*580*510mm | 720*580*410mm*4; 720*580*510mm |
| Gross Weight | 32kg; 21kg; 18kg; 18kg; 33kg | 32kg; 23kg; 18kg; 18kg; 33kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.
Flow Cell Volume: Volume 10.0μl; adopts cone structure /With optional temperature control module; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.