Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Automatic Thermal Desorption Instrument is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-TD50A. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-TD50A |
|---|---|
| Primary Desorption Temperature | RT~400℃, incremental 1°C any set |
| Injection System Temperature | RT~300℃, incremental 1°C any set |
| Sample Transfer Tube Temperature | RT~300℃, incremental 1°C any set |
| Secondary Desorption Temperature | RT~400℃, incremental 1°C any set; Heating rate>2000℃/min |
| Cold Trap Temperature | -35~50°C, incremental 1°C any set(using electronic refrigeration device, no need for liquid nitrogen refrigeration) |
| Temperature Control Accuracy | ±1℃ |
| Temperature Control Gradient | ±1℃ |
| Sample Position | 50 positions |
| Desorption Recovery Rate | >98%(related to components) |
| Backflushing Cleaning Flow | 0~100ml/min(continuously adjustable) |
| Analog Sampling Flow | 100ml/min |
| Power Supply | AC220V, 50/60Hz (Standard); 110V, 60Hz(Optional, External transformer) |
| External Size(W*D*H) | 432*508*600mm |
| Net Weight | 39kg |
| Package Size(W*D*H) | 760*610*800mm |
| Gross Weight | 55kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Flow Cell Volume: 8.0μl; Wavelength Range: 190~680nm. Match the analytical method, detector, column and sample-handling configuration.
Temperature Control Range of Water Trap: RT~240 ℃, with an increment of 1°C, the heating power is about 100W;; Temperature Control Range of Valve Injection System: RT~220 ℃, with an increment of 1°C, the heating power is about 150W;. Match the analytical method, detector, column and sample-handling configuration.
Flow Cell Volume: Volume 10.0μl; adopts cone structure /With optional temperature control module; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.