BIOBASE High Performance Liquid Chromatography System Agress1100+ is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: Agress1100+(Type I), Agress1100+(Type II). Published details include Wavelength Range: 190~700nm; Temperature Range: Ambient temperature+5~99°C. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Item | Specification |
|---|---|
| Wavelength Range | 190~700nm |
| Light Resource | Deuterium lamp |
| Display | 2*16 LCD |
| Spectral Bandwidth | 8nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Repeatability | ≤1nm |
| Set Fan of Wavelength-time Program | 0.1~999.9min |
| Response Time | 0.1~5.0s |
| Noise | ≤±1×10⁻⁵ AU (Empty flow cell, 254nm, constant ambient temperature) |
| Drift | ≤1.5×10⁻⁴ AU/h (Empty flow cell, 254nm, constant ambient temperature) |
| Linearity Range | ≥1.8AU (5%, 254nm) |
| Optical Path of Flow Cell | 10mm |
| Withstand Voltage of Flow Cell | ≤8MPa |
| Communication Mode | RS232 or USB |
| Item | Specification |
|---|---|
| Flow Rate | 0.001 - 10.000 mL/min (Step: 0.001 mL/min) |
| Accuracy | ≤ ±0.3% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Precision | ≤ 0.085% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Max Pressure | 45MPa(0.001~5.000mL/min) 20MPa(5.001~10.000mL/min) |
| Pressure Accuracy | ±3% or <±0.8 MPa |
| Pressure Pulsation | ≤1% |
| Leak-proofing Capability | Pressure drop≤1.5MPa (40MPa, 10min) |
| Communication mode | RS-485 |
| Dimension/Net Weight | 420*260*160mm/14kg |
| Power Supply | AC220V, 50Hz |
| Power | 80W |
| Item | Specification |
|---|---|
| Temperature Range | Ambient temperature+5~99°C |
| Setting Precision | 0.1°C |
| Temperature Accuracy | ≤±0.5°C |
| Temperature Stability | ≤0.2°C |
| Communication Interface | RS-485 |
| No. | Items | Specifications |
|---|---|---|
| 1 | Injection range | 0~100μL, 500μL, 2mL |
| 2 | Injection repeatability | RSD<0.3% Full sample loop injection (standard conditions) RSD<0.5% Partial volume injection (lossy injection, standard conditions) RSD<1.0% Partial volume injection (without loss, standard conditions) |
| 3 | Injection linearity | R²>0.999 |
| 4 | Sample residue | <0.01% |
| 5 | Highest pressure | 45MPa |
| 6 | Communication method | UDP network communication |
| 7 | Injection trigger | Digital mode, analog mode |
| Model | Agress1100+(Type I) | Agress1100+(Type II) |
|---|---|---|
| Pump | P1100+*1 | P1100+*2 |
| Detector | D1100+*1 | D1100+*1 |
| Sampler Injector | Rheodyne 7725i*1 | Rheodyne 7725i*1 |
| Valve Mounting Frame | VB1100+*1 | VB1100+*1 |
| Solvent Bottle Tray | T1100+*1 | T1100+*1 |
| Workstation | Kromstation*1 | Kromstation*1 |
| System Toolkit | Agress1100+*1 | Agress1100+*1 |
| Column | Supersil ODS2 5μm 4.6*250mm*1 | Supersil ODS2 5μm 4.6*250mm*1 |
| Gradient Mixer | / | TD-1-15*1 |
| Power Supply | AC220V±10%, 50Hz | AC220V±10%, 50Hz |
| Optional Accessory | S1100+ autosampler, column, O1120+ column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle | S1100+ autosampler, column, O1120+ column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle |
| Packing Size(W*D*H) | 580*400*280mm 580*400*280mm 580*400*280mm | 580*400*280mm 580*400*280mm 580*400*280mm 580*400*280mm |
| Gross Weight | 16kg 16kg 8kg | 16kg 16kg 16kg 8kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Mixed Volume: 750μL; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.
Temperature range: Ambient+5~85℃; Wavelength Range: 190~800nm. Match the analytical method, detector, column and sample-handling configuration.