Skip to main content

BIOBASE Gas Chromatograph BK-GC908

Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Gas Chromatograph BK-GC908

BIOBASE Gas Chromatograph BK-GC908 is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-GC908. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelBK-GC908BK-GC908
OvenTemperature RangeRT+2~450℃
OvenTemperature Control Accuracy0.01℃
OvenTemperature Program≥99 levels, 100 platform (expandable)
OvenMaximum Temperature Heating Rate250ºC/min
OvenTemperature Control SystemAn 8-channel independent temperature control system with automatic temperature protection function
Selectable Detector TypesFlame Ionization Detector (FID)Operating temperature: 450℃
Selectable Detector TypesFlame Ionization Detector (FID)Detection limit ≤ 1.1 pg C/s (n-hexadecane)
Selectable Detector TypesFlame Ionization Detector (FID)Baseline drift (30 min) ≤ 2*10⁻¹³ A
Selectable Detector TypesFlame Ionization Detector (FID)Baseline noise ≤2*10⁻^(14)A
Selectable Detector TypesFlame Ionization Detector (FID)Dynamic linear range ≥10⁷
Selectable Detector TypesFlame Ionization Detector (FID)Automatic ignition function
Selectable Detector TypesThermal Conductivity Detector (TCD)Sensitivity≥10,000 mV·mL/mg
Selectable Detector TypesThermal Conductivity Detector (TCD)Baseline drift (30 min): ≤0.2 mV
Selectable Detector TypesThermal Conductivity Detector (TCD)Baseline noise: ≤0.05mV
Selectable Detector TypesThermal Conductivity Detector (TCD)Dynamic linear range: ≥10⁵
Selectable Detector TypesThermal Conductivity Detector (TCD)Safety protection: Gas bridging current protection function
Selectable Detector TypesFlame Photometric Detector (FPD)Maximum operating temperature: 450℃
Selectable Detector TypesFlame Photometric Detector (FPD)Limits of detection: P ≤ 80 fg/s (methyl parathion), S ≤ 8 pg/s (methyl parathion)
Selectable Detector TypesFlame Photometric Detector (FPD)Dynamic linear range: P≥10³; S≥10²
Selectable Detector TypesFlame Photometric Detector (FPD)Equipped with automatic ignition function
Selectable Detector TypesElectron Capture Detector (ECD)Radioactive source: 63Ni
Selectable Detector TypesElectron Capture Detector (ECD)Maximum operating temperature: 400℃
Selectable Detector TypesElectron Capture Detector (ECD)Limit of detection: ≤1.0*10^(-14) g/mL (γ-666)
Selectable Detector TypesElectron Capture Detector (ECD)Dynamic linear range: ≥10⁴
Selectable Detector TypesNitrogen-phosphorus Detector (NPD)Maximum operating temperature: 400℃
Selectable Detector TypesNitrogen-phosphorus Detector (NPD)Limit of detection: N: ≤1*10⁻¹² g(N)/s (azobenzene); P: ≤5*10⁻¹³ g(P)/s (malathion)
Selectable Detector TypesNitrogen-phosphorus Detector (NPD)Dynamic linear range: N≥10³, P≥10³
Selectable Sample Injection MethodIt can be used with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc.It can be used with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc.
Standard AccessoriesFID detector, general chromatography workstation software, capillary sampler, startup toolkitFID detector, general chromatography workstation software, capillary sampler, startup toolkit
Optional AccessoriesSample injection system, TCD, ECD, FPD and NPD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace samplerSample injection system, TCD, ECD, FPD and NPD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace sampler
Power SupplyAC220V, 50/60HzAC220V, 50/60Hz
Product Size(W*D*H)670*580*500mm670*580*500mm
Net Weight60kg60kg
Packing Size(W*D*H)840*720*750mm840*720*750mm
Gross Weight73kg73kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category