Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE High Performance Liquid Chromatography System EClassical 3100 is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: EClassical 3100 (Type I), EClassical 3100 (Type II), EClassical 3100 (Type III), EClassical 3100 (Type IV). Published details include Mixed Volume: 750μL; Wavelength Range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Item | Specification |
|---|---|
| Flow Range | 0.001~10.000mL/min(step 0.001 mL/min) |
| Accuracy | ≤±0.2% |
| Precision | ≤0.075%RSD |
| Pressure Range | 0-45MPa |
| Power | AC220V±10%, 50 Hz/80W |
| Dimensions/Weight | 420*300*175mm (W*D*H)/12kg |
| Item | Specification |
|---|---|
| Flow Range | 0.001~10.000mL/min(step 0.001mL/min) |
| Accuracy | ≤±0.1%(1.000mL/min,8.5MPa,water, ambient temperature); ≤±2.0%(0.001mL/min~10.000mL/min,8.5MPa,water, ambient temperature) |
| Precision ; | ≤0.075%(1.000mL/min,8.5MPa,water, ambient temperature); ≤0.1%(0.100mL/min~10.000mL/min,8.5MPa,water, ambient temperature) |
| Maximum Working Pressure | 63MPa |
| Communication Methods | UDP Network Communication |
| Mixed Volume | 750μL |
| Power | AC220V±10%, 50Hz/100W |
| Dimensions/Weight | 400*300*180mm (W*D*H)/15kg |
| Item | Specification |
|---|---|
| Linearity Range | ≥1.8AU(5%) (254nm) |
| Wavelength Range | 190~700nm |
| Noise | ≤±0.5*10⁻⁵ AU |
| Drift | ≤1.0*10⁻⁴ AU/h |
| Cell Path Length ; | 10mm ; |
| Power | AC220V±10%, 50Hz/100W |
| Dimensions/Weight | 420*300*175mm (W*D*H)/16kg |
| Item | Specification |
|---|---|
| Linearity Range | ≥2.0 AU(254nm) |
| Wavelength Range | 190~800nm |
| Noise | ≤±1.0*10⁻⁵ AU |
| Drift | ≤3*10⁻⁴ AU/h |
| Power | AC220V±10%, 50Hz/80W |
| Dimensions/Weight | 500*300*175mm (W*D*H)/18kg |
| Item | Specification |
|---|---|
| Temperature Range | Ambient+5~80℃ |
| Accuracy | ±0.3 ℃ |
| Precision | ≤0.1 ℃ |
| Power | AC220V±10%, 50Hz/130W |
| Dimensions/Weight | 420*300*120mm (W*D*H)/7kg |
| Model | EClassical 3100 (Type I) | EClassical 3100 (Type II) | EClassical 3100 (Type III) | EClassical 3100 (Type IV) |
|---|---|---|---|---|
| Pump | P3100*1 | P3100*2 | P3130*1(With mixer) | P3130*1(With mixer) |
| Detector | UV3100*1 | UV3100*1 | UV3100*1 | DAD3100(512-diode array)*1 |
| Flow Cell | SC3100*1 | SC3100*1 | SC3100*1 | SC3000*1 |
| Gradient Mixer | / | TD-1-15*1 | / | / |
| Solvent Bottle Tray | TP3100*1 | TP3100*1 | TP3100*1 | TP3100*1 |
| Sampler Injector | Rheodyne 7725i*1 | Rheodyne 7725i*1 | Rheodyne 7725i*1 | Rheodyne 7725i*1 |
| Column | Supersil ODS2 5μm ID4.6mm*200mm1 | Supersil ODS2 5μm ID4.6mm*200mm1 | Supersil ODS2 5μm ID4.6mm*200mm1 | Supersil ODS2 5μm ID4.6mm*200mm1 |
| Workstation | Kromstation*1 | Kromstation*1 | Kromstation*1 | Kromstation+PDA |
| AD Adapter | / | / | / | AD3000 adapter |
| Valve Mounting Frame | ZJ-1*1 | ZJ-1*1 | ZJ-1*1 | ZJ-1*1 |
| Degasser | / | / | DG3110*1 | DG3110*1 |
| System Kit | EClassical 3100*1 | EClassical 3100*1 | EClassical 3100*1 | EClassical 3100*1 |
| Power Supply | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz |
| Optional Accessory | S3100 autosampler, column, O3100 column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle | S3100 autosampler, column, O3100 column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle | S3100 autosampler, column, O3100 column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle | S3100 autosampler, column, O3100 column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle |
| Package Size (W*D*H) | 600*440*380mm*2; 580*400*280mm*1 | 600*440*380mm*3; 580*400*280mm*1 | 600*440*380mm*2 320*190*230mm*1 500*360*210mm*1 | 600*440*380mm*3 ; |
| Gross Weight | 15kg; 16kg; 9kg | 15kg 15kg; 19kg; 9kg | 19kg 18kg; 4kg; 4kg | 18kg; 18kg; 16.5kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temperature range: Ambient+5~85℃; Wavelength Range: 190~800nm. Match the analytical method, detector, column and sample-handling configuration.
Wavelength Range: 190~700nm; Temperature Range: Ambient temperature+5~99°C. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.