Brand: BIOBASE | Category: Medical Equipment

BIOBASE Electrolyte Analyzer BKE Series is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: BKE-A/B/C/D, BKE-E/F/L, BKE-A, BKE-B, BKE-C, BKE-D. Compare the remaining models in the specification tables. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BKE-A/B/C/D | BKE-E/F/L |
|---|---|---|
| Sample | Serum, plasma, whole blood, cerebrospinal fluid and dilute urine | Serum, plasma, whole blood, cerebrospinal fluid and dilute urine |
| Measuring Speed | ≤25s | ≤25s |
| Analysis Method | Ion selective electrode(ISE) | Ion selective electrode(ISE) |
| Sample Volume | 60~150μl | 200μl |
| Sample Position | 30 sample positions, 5 emergency positions(Only for BKE-B/D/F/L) | 30 sample positions, 5 emergency positions(Only for BKE-B/D/F/L) |
| Injection mode | Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection | Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection |
| Storage | Up to 50,000 test results | Up to 50,000 test results |
| Printer | Build-in thermal printer | Build-in thermal printer |
| Interface | RS232 port for LIS | RS232 port for LIS |
| Display | 7-inch high-definition touch screen | 7-inch high-definition touch screen |
| Language | Chinese and English, other languages can be customized | Chinese and English, other languages can be customized |
| Calibration | Automatic and manual calibration | Automatic and manual calibration |
| Other Function | Sample volume detection | Sample volume detection |
| Power Supply | AC100~240V, 50/60Hz, 70VA | AC100~240V, 50/60Hz, 70VA |
| Temperature | +10~+40℃ | +10~+40℃ |
| Relative Humidity | ≤80 % | ≤80 % |
| Atmospheric Pressure | 86~106kPa | 86~106kPa |
| Model | BKE-A | BKE-B | BKE-C | BKE-D |
|---|---|---|---|---|
| Test Items | K+, Na+, Cl- | K+, Na+, Cl- | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH |
| Sample Tray | No | Yes | No | Yes |
| External Size(W*D*H)(mm) | 405*214*471 | 682*287*471 | 405*214*471 | 682*287*471 |
| Net Weight(kg) | 12.48 | 15.11 | 12.48 | 15.11 |
| Package Size(W*D*H)(mm) | Instrument: 500*390*530 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*720 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*530 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*720 Reagent: 220*160*120, 220*160*120 |
| Gross Weight(kg) | Instrument: 16.08 Reagent: 1.7, 0.9 | Instrument: 19.31 Reagent: 1.7, 0.9 | Instrument: 16.08 Reagent: 1.7, 0.9 | Instrument: 19.31 Reagent: 1.7, 0.9 |
| Model | BKE-E | BKE-F | BKE-L |
|---|---|---|---|
| Test Items | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+, Mg2+ |
| Sample Tray | No | Yes | Yes |
| External Size(W*D*H)(mm) | 405*214*471 | 682*287*471 | 682*287*471 |
| Net Weight(kg) | 13.13 | 15.76 | 15.76 |
| Package Size(W*D*H)(mm) | Instrument: 500*390*530 Reagent: 280*135*210, 220*160*120 | Instrument: 500*390*720 Reagent: 280*135*210, 220*160*120 | Instrument: 500*390*720 Reagent: 280*135*210, 220*160*120 |
| Gross Weight(kg) | Instrument: 16.73 Reagent: 2.2, 1.2 | Instrument: 19.96 Reagent: 2.2, 1.2 | Instrument: 19.96 Reagent: 2.2, 1.2 |
| Items | Measuring Range | Resolution |
|---|---|---|
| K+ | 0.5~20.0mmol/L | 0.01mmol/L |
| Na+ | 15~200mmol/L | 0.01mmol/L |
| Cl- | 15~200mmol/L | 0.01mmol/L |
| Ca2+ | 0.1~6.0mmol/L | 0.01mmol/L |
| pH | 4~9 | 0.01 |
| TCO2 | 2.0~70.0mmol/L | 0.1mmol/L |
| Li+ | 0.1~6.0mmol/L | 0.01mmol/ L |
| Mg2+ | 0.1~4.0mmol/L | 0.01mmol/ L |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Sample Volume: Total parameter consumption≤140μL, minimum sample consumption 50μL; Storage Capacity: 150,000 tests. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.