Brand: BIOBASE | Category: Medical Equipment
BIOBASE Blood Gas and Chemistry Analyzer is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: PT2000 Pro/PT2000 X5 Pro. Published details include Sample Volume: Total parameter consumption≤140μL, minimum sample consumption 50μL; Storage Capacity: 150,000 tests. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | PT2000 Pro/PT2000 X5 Pro |
|---|---|
| Throughput | Results in 60 seconds after sample aspiration |
| Sample Volume | Total parameter consumption≤140μL, minimum sample consumption 50μL |
| Display | 12.1 inches display |
| Battery | Built-in lithium battery supports measurement of ≥20 samples to handle special situations such as sudden power outages without affecting onboard testing |
| Barcode Scanning | Built-in barcode scanning module, external barcode scanner also supported |
| Interface | 4 USB ports, 1 Ethernet port, 1 RS232 serial port |
| Storage Capacity | 150,000 tests |
| Communication Link | Bidirectional connectivity with data management systems such as LIS/HIS |
| Operation Environment | 10~31℃ |
| Power Supply | AC100~240V, 50/60Hz |
| Product Size(W*D*H) | 326*320*505mm |
| Net Weight | 17.8kg |
| Packing Size(W*D*H) | 440*440*645mm |
| Gross Weight | 20.3kg |
| Parameters | Measuring range | Unit |
|---|---|---|
| pH | 6.500-8.000 | - |
| pCO2 | 10.0-150.0 | mmHg |
| pO2 | 10.0-700.0 | mmHg |
| Na+ | 90.0-190.0 | mmol/L |
| K+ | 1.00-19.00 | mmol/L |
| Ca2+ | 0.250-4.250 | mmol/L |
| Cl – | 40.0-160.0 | mmol/L |
| Glu | 0.2-38.9 | mmol/L |
| Lac | 0.3-20.0 | mmol/L |
| Hct | 10.0-75.0 | %PCV |
| tHb | 3.0-23.0 | g/dL |
| O2Hb | 0.5-100.0 | % |
| COHb | 0.5-75.0 | % |
| MetHb | 0.7-30.0 | % |
| HHb | 1.0-100.0 | % |
| tBili | 0.2-40.0 | mg/dL |
| sO2 | 0.5-100.0 | % |
| 40 calculated parameters: cH+, cH+ (T), pH(T), pCO2(T), pO2(T), HCO3- act, HCO3-std, BB(B), BE(B), BE(ecf), ctCO2, Ca++(7.4), sO2(est), AnGap, tHb(est), pO2(A-a), pO2(A-a) (T), pO2(a/A), pO2(a/A) (T), RI, RI (T), pO2/FIO2, pO2(T)/FIO2, PAO2, pO2(A,T), p50(st), ctO2(a-v), Qs/Qt, ctCO2(P), pH(st), mOsm, pCO2(gap), BEact, Lacclearance 1h, mOsmopt gap | 40 calculated parameters: cH+, cH+ (T), pH(T), pCO2(T), pO2(T), HCO3- act, HCO3-std, BB(B), BE(B), BE(ecf), ctCO2, Ca++(7.4), sO2(est), AnGap, tHb(est), pO2(A-a), pO2(A-a) (T), pO2(a/A), pO2(a/A) (T), RI, RI (T), pO2/FIO2, pO2(T)/FIO2, PAO2, pO2(A,T), p50(st), ctO2(a-v), Qs/Qt, ctCO2(P), pH(st), mOsm, pCO2(gap), BEact, Lacclearance 1h, mOsmopt gap | 40 calculated parameters: cH+, cH+ (T), pH(T), pCO2(T), pO2(T), HCO3- act, HCO3-std, BB(B), BE(B), BE(ecf), ctCO2, Ca++(7.4), sO2(est), AnGap, tHb(est), pO2(A-a), pO2(A-a) (T), pO2(a/A), pO2(a/A) (T), RI, RI (T), pO2/FIO2, pO2(T)/FIO2, PAO2, pO2(A,T), p50(st), ctO2(a-v), Qs/Qt, ctCO2(P), pH(st), mOsm, pCO2(gap), BEact, Lacclearance 1h, mOsmopt gap |
| NO. | Cartridge Model | Test Items | Specification |
|---|---|---|---|
| 1 | PTII-3 | pH, pCO2, pO2 | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 2 | PTII-4L | pH, pCO2, pO2, Lac | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 3 | PTII-4H | pH, pCO2, pO2, Hct | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 4 | PTII-5 | pH, pCO2, pO2, Lac, Hct | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 5 | PTII-6 | PH, pO2, pCO2, Hct, Lac,Glu | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 6 | PTII-6E | pH, Na+, K+, Ca2+, Cl-, Hct | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 7 | PTII-8 | pH, pO2, pCO2, Hct, Na+, K+, Ca2+, Cl- | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 8 | PTII-9 | pH, pO2, pCO2, Hct, Na+, K+, Ca2+, Cl-, Lac | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 9 | PTII-10 | pH, pO2, pCO2, Hct, Na+, K+, Ca2+, Cl-, Lac, Glu | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 10 | PTII-12TY | pH, pO2, pCO2, Hct, Lac, Glu, tHb, O2Hb, COHb, MetHb, HHb, sO2 | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 11 | PTII-13 | pH, pO2, pCO2, Hct, Lac, Glu, tHb, O2Hb, COHb, MetHb, HHb, sO2, tBili | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 12 | PTII-16 | pH, pO2, pCO2, Hct, Na+, K+, Ca2+, Cl-, Lac, Glu, tHb, O2Hb, COHb, MetHb, HHb, sO2 | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| 13 | PTII-17 | pH, pO2, pCO2, Hct, Na+, K+, Ca2+, Cl-, Lac, Glu, tHb, O2Hb, COHb, MetHb, HHb, tBili, sO2 | 25 tests/kit, 60 tests/kit, 100 tests/kit, 200 tests/kit, 300 tests/kit, 400 tests/kit, 600 tests/kit |
| Cartridge Specification | Cartridge Specification | Cartridge Specification | Cartridge Specification |
| Storage | Storage | Storage at room temperature 15~25℃, protected from light and moisture | Storage at room temperature 15~25℃, protected from light and moisture |
| Shelf Life | Shelf Life | Shelf life: 270 days; Onboard Shelf-life: 30 days(25/60/100/200/300/400/500T), 21 days(600T) | Shelf life: 270 days; Onboard Shelf-life: 30 days(25/60/100/200/300/400/500T), 21 days(600T) |
| Consumables | Consumables | No consumables except integrated cartridge; no need for additional electrode, electrode membrane, or electrode card replacement | No consumables except integrated cartridge; no need for additional electrode, electrode membrane, or electrode card replacement |
| Calibration | Calibration | Automatic one-point and two-point calibration | Automatic one-point and two-point calibration |
| Quality Control | Quality Control | Built-in quality control package supports automatic quality control and customizable settings; one-click generation of quality control charts or reports with automatic data processing | Built-in quality control package supports automatic quality control and customizable settings; one-click generation of quality control charts or reports with automatic data processing |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Sample Volume: 150μL; Storage Capacity: 100000+ tests. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.