BIOBASE Dispensing Peristaltic Pump BT-F Series is listed in VVON's laboratory pumps & gas generators range for Bangladesh. Published models: BT101F, BT301F, BT601F. Match flow, pressure or vacuum, purity and connected-instrument requirements. For a quotation, send the connected instrument, flow, pressure or vacuum, purity and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
ModelBT101FBT301FBT601F
Flow Range0.0001~720ml/min0.005~1750ml/min0.006~3000ml/min
Rotation Range0.1~150rpm0.1~350rpm0.1~600rpm
Speed Resolution0.1rpm0.1rpm0.1rpm
Dispensed Liquid Volume Range0.05ml ~9999I0.05ml ~9999I0.05ml ~9999I
Dispensed Frequency Range1 to 999 times, "0" means infinite loop1 to 999 times, "0" means infinite loop1 to 999 times, "0" means infinite loop
Dispensed Interval Time0.1~999.9 seconds/minute/hour, time unit is adjustable0.1~999.9 seconds/minute/hour, time unit is adjustable0.1~999.9 seconds/minute/hour, time unit is adjustable
Speed Accuracy<±0.2%<±0.2%<±0.2%
Power SupplyAC100~240V, 50Hz/60HzAC100~240V, 50Hz/60HzAC100~240V, 50Hz/60Hz
Power<30W<40W<50W
External Control InterfaceExternal control input level 5V, 12V(standard), 24V(optional)External control input level 5V, 12V(standard), 24V(optional)External control input level 5V, 12V(standard), 24V(optional)
Communication InterfaceExternal control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocolExternal control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocolExternal control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocol
Working EnvironmentAmbient temperature 0~40°C, relative humidity <80%Ambient temperature 0~40°C, relative humidity <80%Ambient temperature 0~40°C, relative humidity <80%
Protection LevelIP31IP31IP31
Overall Dimensions(L*W*H)261*180*197mm261*180*197mm261*180*197mm
Drive Weight4.5kg4.7kg4.9kg
Packing Size430*290*320mm430*290*320mm430*290*320mm
Gross Weight8kg8kg8kg
Manufacturer specifications 2
Driver ModelApplicable; Pump HeadNumber; Of ChannelsApplicable HoseSingle Channel; Flow Rate(ml/min)
BT101FDG/DS(6 rollers)1, 2, 4Wall 0.8~1mm, ID≤3.17mm0.00016~49
BT101FDG/DS(10 rollers)1, 2, 4Wall 0.8~1mm, ID≤3.17mm0.00011~32
BT101FYZ15T1, 213#14#19#16#25#17#18#0.005~641
BT101FYT251114#116#15#24#35#36#0.024~750
BT301FYZ15T113#14#19#16#25#17#18#0.005~1495
BT301FYT251114#116#15#24#35#36#0.024~1750
BT601FYZ15T113#14#19#16#25#17#18#0.005~2562
BT601FYT251114#116#15#24#35#36#0.024~3000

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category