Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Dispensing Peristaltic Pump BT-F Series is listed in VVON's laboratory pumps & gas generators range for Bangladesh. Published models: BT101F, BT301F, BT601F. Match flow, pressure or vacuum, purity and connected-instrument requirements. For a quotation, send the connected instrument, flow, pressure or vacuum, purity and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BT101F | BT301F | BT601F |
|---|---|---|---|
| Flow Range | 0.0001~720ml/min | 0.005~1750ml/min | 0.006~3000ml/min |
| Rotation Range | 0.1~150rpm | 0.1~350rpm | 0.1~600rpm |
| Speed Resolution | 0.1rpm | 0.1rpm | 0.1rpm |
| Dispensed Liquid Volume Range | 0.05ml ~9999I | 0.05ml ~9999I | 0.05ml ~9999I |
| Dispensed Frequency Range | 1 to 999 times, "0" means infinite loop | 1 to 999 times, "0" means infinite loop | 1 to 999 times, "0" means infinite loop |
| Dispensed Interval Time | 0.1~999.9 seconds/minute/hour, time unit is adjustable | 0.1~999.9 seconds/minute/hour, time unit is adjustable | 0.1~999.9 seconds/minute/hour, time unit is adjustable |
| Speed Accuracy | <±0.2% | <±0.2% | <±0.2% |
| Power Supply | AC100~240V, 50Hz/60Hz | AC100~240V, 50Hz/60Hz | AC100~240V, 50Hz/60Hz |
| Power | <30W | <40W | <50W |
| External Control Interface | External control input level 5V, 12V(standard), 24V(optional) | External control input level 5V, 12V(standard), 24V(optional) | External control input level 5V, 12V(standard), 24V(optional) |
| Communication Interface | External control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocol | External control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocol | External control analog 0~5V(standard), 0~10V, 4~20mA(optional) RS485 communication, compatible with modbus protocol |
| Working Environment | Ambient temperature 0~40°C, relative humidity <80% | Ambient temperature 0~40°C, relative humidity <80% | Ambient temperature 0~40°C, relative humidity <80% |
| Protection Level | IP31 | IP31 | IP31 |
| Overall Dimensions(L*W*H) | 261*180*197mm | 261*180*197mm | 261*180*197mm |
| Drive Weight | 4.5kg | 4.7kg | 4.9kg |
| Packing Size | 430*290*320mm | 430*290*320mm | 430*290*320mm |
| Gross Weight | 8kg | 8kg | 8kg |
| Driver Model | Applicable; Pump Head | Number; Of Channels | Applicable Hose | Single Channel; Flow Rate(ml/min) |
|---|---|---|---|---|
| BT101F | DG/DS(6 rollers) | 1, 2, 4 | Wall 0.8~1mm, ID≤3.17mm | 0.00016~49 |
| BT101F | DG/DS(10 rollers) | 1, 2, 4 | Wall 0.8~1mm, ID≤3.17mm | 0.00011~32 |
| BT101F | YZ15T | 1, 2 | 13#14#19#16#25#17#18# | 0.005~641 |
| BT101F | YT25 | 1 | 114#116#15#24#35#36# | 0.024~750 |
| BT301F | YZ15T | 1 | 13#14#19#16#25#17#18# | 0.005~1495 |
| BT301F | YT25 | 1 | 114#116#15#24#35#36# | 0.024~1750 |
| BT601F | YZ15T | 1 | 13#14#19#16#25#17#18# | 0.005~2562 |
| BT601F | YT25 | 1 | 114#116#15#24#35#36# | 0.024~3000 |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Laboratory Pumps & Gas Generators by BIOBASE. Match flow, pressure or vacuum, purity and connected-instrument requirements.
Laboratory Pumps & Gas Generators by BIOBASE. Match flow, pressure or vacuum, purity and connected-instrument requirements.
Laboratory Pumps & Gas Generators by BIOBASE. Match flow, pressure or vacuum, purity and connected-instrument requirements.