Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Cytotoxic Safety Cabinet 11224BBC86 11234BBC86 11244BBC86 is listed in VVON's biosafety cabinets range for Bangladesh. Published models: 11224 BBC 86, 11234 BBC 86, 11244 BBC 86. Compare cabinet class, usable width, exhaust arrangement and installation requirements. For a quotation, send the sample workflow, required cabinet class, working width and room ventilation. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | 11224 BBC 86 | 11234 BBC 86 | 11244 BBC 86 |
|---|---|---|---|
| External Size(W*D*H) | 1087*760*2100mm | 1380*760*2100mm | 1877*760*2100mm |
| Internal Size(W*D*H) | 910*600*630mm | 1220*600*630mm | 1700*600*630mm |
| Tested Opening | Safety height 200mm(8") | Safety height 200mm(8") | Safety height 200mm(8") |
| Max Opening | 440mm(17") | 440mm(17") | 440mm(17") |
| Inflow Velocity | 0.53±0.025m/s | 0.53±0.025m/s | 0.53±0.025m/s |
| Down Flow Velocity | 0.33±0.025m/s | 0.33±0.025m/s | 0.33±0.025m/s |
| Exhaust Volume | 347m³/h | 465m³/h | 648m³/h |
| Air Supply Filter | ULPA filter, efficiency>99.9995% for particle size at 0.12μm | ULPA filter, efficiency>99.9995% for particle size at 0.12μm | ULPA filter, efficiency>99.9995% for particle size at 0.12μm |
| Exhaust Filter | ULPA filter: first exhaust filter: 0.12μm efficiency 99.9995% HEPA filter: secondary exhaust filter: 0.3μm efficiency 99.995% | ULPA filter: first exhaust filter: 0.12μm efficiency 99.9995% HEPA filter: secondary exhaust filter: 0.3μm efficiency 99.995% | ULPA filter: first exhaust filter: 0.12μm efficiency 99.9995% HEPA filter: secondary exhaust filter: 0.3μm efficiency 99.995% |
| Alarm | Abnormal airflow velocity, Filter replacement, Front window at unsafe height; High filter pressure alarm | Abnormal airflow velocity, Filter replacement, Front window at unsafe height; High filter pressure alarm | Abnormal airflow velocity, Filter replacement, Front window at unsafe height; High filter pressure alarm |
| Noise | ≤67dB | ≤67dB | ≤67dB |
| Water&Gas Tap | Water tap*1, Gas tap*1 | Water tap*1, Gas tap*1 | Water tap*1, Gas tap*1 |
| UV Lamp | 20W*1 | 30W*1 | 40W*1 |
| UV Lamp | Emission of 253.7 nanometers for most efficient decontamination UV life indicator, UV timer | Emission of 253.7 nanometers for most efficient decontamination UV life indicator, UV timer | Emission of 253.7 nanometers for most efficient decontamination UV life indicator, UV timer |
| LED Lamp | 12W*2 | 14W*2 | 16W*2 |
| Illumination | ≥1000Lux | ≥1000Lux | ≥1000Lux |
| Consumption | 700W | 900W | 1300W |
| Waterproof Socket | Two, total load of two sockets: ≤500W | Two, total load of two sockets: ≤500W | Two, total load of two sockets: ≤500W |
| Display | LCD display | LCD display | LCD display |
| Control System | Microprocessor | Microprocessor | Microprocessor |
| Humidity and Temperature | Humidity and temperature can be displayed on the control panel | Humidity and temperature can be displayed on the control panel | Humidity and temperature can be displayed on the control panel |
| Material | Work Area: 304 stainless steel Main Body: cold-rolled steel with anti-bacteria powder coating | Work Area: 304 stainless steel Main Body: cold-rolled steel with anti-bacteria powder coating | Work Area: 304 stainless steel Main Body: cold-rolled steel with anti-bacteria powder coating |
| Front Window | Motorized, two-layer laminated toughened glass≥6mm, anti-UV | Motorized, two-layer laminated toughened glass≥6mm, anti-UV | Motorized, two-layer laminated toughened glass≥6mm, anti-UV |
| Caster | Footmaster caster | Footmaster caster | Footmaster caster |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
| Standard Accessory | Base stand, Drain valve, Waterproof sockets*2, Remote control, LED lamp*2, UV lamp*2, Water tap, Gas tap | Base stand, Drain valve, Waterproof sockets*2, Remote control, LED lamp*2, UV lamp*2, Water tap, Gas tap | Base stand, Drain valve, Waterproof sockets*2, Remote control, LED lamp*2, UV lamp*2, Water tap, Gas tap |
| Optional Accessory | Armrest, Formalin fumigation sterilizer, Infrared sterilizer, Airflow tester | Armrest, Formalin fumigation sterilizer, Infrared sterilizer, Airflow tester | Armrest, Formalin fumigation sterilizer, Infrared sterilizer, Airflow tester |
| Gross Weight | 320kg | 371kg | 430kg |
| Package Size(W*D*H) | 1240*910*2280mm | 1540*910*2280mm | 2050*910*2260mm |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Biosafety Cabinets by BIOBASE. Compare cabinet class, usable width, exhaust arrangement and installation requirements.
Biosafety Cabinets by BIOBASE. Compare cabinet class, usable width, exhaust arrangement and installation requirements.
Biosafety Cabinets by BIOBASE. Compare cabinet class, usable width, exhaust arrangement and installation requirements.