Brand: BIOBASE | Category: Medical Equipment

BIOBASE BK-3000 Automatic Cryostat Microtome is listed in VVON's histology & pathology equipment range for Bangladesh. Published models: BK3000. Published details include Temperature control range of sample chuck: 10℃ ~ -50℃. Match specimen throughput, preparation steps and consumables to the histology workflow. For a quotation, send the specimen workload, preparation method, accessories and consumables. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK3000 |
|---|---|
| Chamber temperature | 10℃ ~ -50℃ |
| Freezing shelf temperature | 0℃ ~ -50℃ |
| Temperature control range of sample chuck | 10℃ ~ -50℃ |
| Additional semiconductor refrigeration in the freezer | -60℃ |
| Number of freezing station | 36 pcs |
| Pelletier number | 8 pcs |
| Semiconductor fast cooling working time | 15 minutes |
| Maximum specimen size | 55mm×80mm |
| Vertical stroke | 65mm |
| Horizontal stroke | 22mm |
| Electric feed speed | 0.9mm/s、0.45mm/s |
| Disinfection method | UV |
| Section thickness range | 0.5μm~100μm Adjustable |
| Section thickness range | 0.5μm~5μm Increment0.5μm |
| Section thickness range | 5μm~20μm Increment1μm |
| Section thickness range | 20μm~40μm Increment2μm |
| Section thickness range | 40μm~100μm Increment5μm |
| Trimming thickness range | 10μm~600μm Adjustable |
| Trimming thickness range | 10μm~50μm Increment5μm |
| Trimming thickness range | 50μm~100μm Increment10μm |
| Trimming thickness range | 100μm~600μm Increment50μm |
| Specimen retraction | 0~100μm Adjustable,Increment5μm |
| Dimension size(mm) | 700×760×1160mm |
| Weight | 135 KG |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Chamber Temp. Range: -10℃ to -40℃; Specimen Head Temp. Range: -10℃ to -40℃. Match specimen throughput, preparation steps and consumables to the histology workflow.
Histology & Pathology Equipment by BIOBASE. Match specimen throughput, preparation steps and consumables to the histology workflow.
Slide Capacity: 1~6pcs. Match specimen throughput, preparation steps and consumables to the histology workflow.