Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Gas Chromatograph BK-GC112A is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: BK-GC112A. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-GC112A | BK-GC112A |
|---|---|---|
| Oven | Capacity | 22L |
| Oven | Temp. Range | RT+5°C~400°C |
| Oven | Temp. Accuracy | ±0.1 °C |
| Oven | Temp. Program | 9 steps |
| Oven | Program Total Time | 9999.9min |
| Oven | Max Temp. Heating Rate | 60°C/min |
| Sample Injector | Temp. Range | RT+7°C~420°C |
| Sample Injector | Column or split injector can be installed | Column or split injector can be installed |
| Sample Injector | Carrier gas flow control type: Constant pressure mode | Carrier gas flow control type: Constant pressure mode |
| Sample Injector | Max. Quantity | 3pcs |
| Sample Injector | Pre Column Pressure Range | 0~400kpa |
| Sample Injector | Pre Column Pressure Accuracy | 0.1kpa |
| Sample Injector | Flow Setting Range | H2: 0~200ml/min |
| Sample Injector | Flow Setting Range | N2: 0~150ml/min |
| Detector | Temp. Range | RT+7°C~420°C |
| Detector | Hydrogen Flame Ionization Detector(FID) | Logarithmic amplifier |
| Detector | Hydrogen Flame Ionization Detector(FID) | High voltage switch control |
| Detector | Hydrogen Flame Ionization Detector(FID) | Baseline signal display |
| Detector | Hydrogen Flame Ionization Detector(FID) | Detection Limit: ≤3*10^(-12)g/s(Sample: n-hexadecane) |
| Detector | Hydrogen Flame Ionization Detector(FID) | Baseline Noise: ≤5*10^(-14)A |
| Detector | Hydrogen Flame Ionization Detector(FID) | Baseline Draft: ≤6*10^(-13)A |
| Detector | Hydrogen Flame Ionization Detector(FID) | Dynamic Range: 10^(7) |
| Detector | Hydrogen Flame Ionization Detector(FID) | RSD: ≤3% |
| Detector | Thermal Conductivity Detector(TCD)(Optional) | Sensitivity: 8000mv.ml/mg(Sample: n-hexadecane) |
| Detector | Thermal Conductivity Detector(TCD)(Optional) | Baseline Noise: ≤0.05mV |
| Detector | Thermal Conductivity Detector(TCD)(Optional) | Baseline Draft: ≤0.15mV/30min |
| Detector | Thermal Conductivity Detector(TCD)(Optional) | Dynamic Range: 10^(5) |
| Power Supply | AC220V±10%, 50Hz | AC220V±10%, 50Hz |
| Standard Accessory | FID detector, Capillary injection system, Chromatography workstation software, RS232 port, LAN port | FID detector, Capillary injection system, Chromatography workstation software, RS232 port, LAN port |
| Optional Accessory | TCD detector, Chromatographic column, Gas purifier | TCD detector, Chromatographic column, Gas purifier |
| Package Size(W*D*H) | 735*725*835mm | 735*725*835mm |
| Gross Weight | 80kg | 80kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by BIOBASE. Match the analytical method, detector, column and sample-handling configuration.