Brand: Infitek | Category: Medical Equipment
Infitek Semi-Automatic Urine Analyzer, UA-SA-200 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| odel | UA-SA-200 | UA-SA-200Vet |
|---|---|---|
| Test Speed | 120 samples/hour | 120 samples/hour |
| Measurement Principle | Ultra-high brightness cold light source, reflectometry principle | Ultra-high brightness cold light source, reflectometry principle |
| Scope of Application | 10,11,12 and 14 parameters | 10,11,12 and 14 parameters |
| Test Items | Glucose (GLU), Bilirubin (BIL), Ketone (KET), Specific gravity (SG), pH, Blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leukocyte (LEU), Ascorbic acid (VC), Creatinine (CRE), Calcium (CAL) and Microalbumin (MAL) | Glucose (GLU), Bilirubin (BIL), Ketone (KET), Specific gravity (SG), pH, Blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leukocyte (LEU), Ascorbic acid (VC), Creatinine (CRE), Calcium (CAL) and Microalbumin (MAL) |
| Record Method | Thermal print/LCD display | Thermal print/LCD display |
| Detection Wavelength | 525nm-660nm | 525nm-660nm |
| Working Environment | Temperature:15°C~35°C, Humidity<85% | Temperature:15°C~35°C, Humidity<85% |
| Power | 50VA | 50VA |
| Data Communication | RS232 interface, can connect with urine sediment analysis system, hospital management system | RS232 interface, can connect with urine sediment analysis system, hospital management system |
| Data Storage | 2000 test results can be stored, can be queried according to the record number | 2000 test results can be stored, can be queried according to the record number |
| Report Mode | International units or conventional units | International units or conventional units |
| Printing | Built-in high-speed thermal printer | Built-in high-speed thermal printer |
| LCD Display | 40*64 dot matrix, 37*13mm | 40*64 dot matrix, 37*13mm |
| External Dimension | 350*285*140mm | 350*285*140mm |
| N.W./G.W. | 2.6kg/4.8kg | 2.6kg/4.8kg |
| Package Dimension (W*D*H) | 500*380*250mm | 500*380*250mm |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
On Board Sample Capacity: 5 racks of 10 tubes (50 samples); Sample Volume: Minimum volume: 3mL. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by Infitek. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Sample Volume: Minimum volume:3mL,Aspiration volume:1mL; Aspiration Volume: 1ml. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.