Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Nano Laser Particle Size Analyzer, DLS PSA-N802 is listed in VVON's particle size rheology & physical analysis range for Bangladesh. Published models: PSA-N802, CR256. Published details include Temperature measuring range: 5℃ to 40℃. Match the material, property, measurement range and sample-preparation method. For a quotation, send the material, property to measure, measurement range and sample preparation. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Item | Function |
|---|---|
| Analysis | Average Particle Diameter, Particle Distribution, Photon Counting Rate etc. |
| Analysis mode | NNSL, Multi-peak, CONTIN |
| Output | It can output the actual particle size distribution. Users can freely set and retrieve percentiles (D10–D100), volume-weighted mean diameter (D[4,3]), surface-weighted mean diameter (D[3,2]), D[2,1], D[1,0], and specific surface area. |
| Model | PSA-N802 |
|---|---|
| Instrument type | Nano |
| Specification | Specification |
| Measuring range | 0.3nm-10000nm |
| Concentration range | 0.1mg/mL to 100mg/mL |
| Accuracy | ≤1% (CRM D50) |
| Repeatability | ≤1% (CRM D50) |
| Design principle | Dynamic Light Scattering (DLS) |
| Standard | ISO 13321, ISO 22412 |
| Audit trail | Optional FDA software |
| Engineering | Engineering |
| Laser | Semiconductor Laser, 532nm, P=30mW |
| Laser safety | Class 1 |
| Detector | Scattering angle 90°, Hamamatsu PMT (19-90℃) |
| Sample cuvette | 1mL to 4mL (10mm×10mm×40mm) |
| Temperature control | 5℃ to 90℃ (±0.1℃) |
| Temperature measuring range | 5℃ to 40℃ |
| Test speed | ≤5min |
| Digital correlator | Digital correlator |
| Model | CR256 |
| Auto-correlation channel | 256 |
| Baseline channel | 4 |
| Physical channel | 5000 |
| Unit delay time | 100ns to 10ms |
| Technical data | Technical data |
| Connect PC, LIMS | Yes |
| Test Report | Word, Excel, Image, etc. |
| Storage environment | Temperature: 15℃ to 30℃; Humidity: <75% |
| Power supply | 220V, 50/60Hz |
| Product dimensions (L×W×H) | 480mm×270mm×170mm |
| Net weight | 12kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.