Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Liquid Chromatograph, HPLC-3100 is listed in VVON's chromatography systems & consumables range for Bangladesh. Published details include Lagging volume: ≤500μL; Wavelength range: 190~700nm. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Flow range | 0.001~10.000mL/min(Set step size 0.001mL/min) |
|---|---|
| Flow Accuracy | ≤±0.2%(1.000mL/min,8.5MPa,Water, room temp) |
| Flow stability | RSD≤0.06%(1.000mL/min,8.5MPa,Water, room temp) |
| Maximum working pressure | 45MPa(0.001~5.000mL/min) 20MPa(5.001~10.000mL/min) |
| Lagging volume | ≤500μL |
| Size/weight | 420×300×175mm(Length×Width×Height)/12kg |
| Power supply/power | AC220V±10%,50Hz/80W |
| Wavelength range | 190~700nm |
|---|---|
| Baseline noise | ≤±0.5×10-5AU(Dry pool、254nm) |
| Baseline drift | ≤1.0×10-4AU/h(Empty pool、254nm、20Hz) |
| Size/weight | 420×300×175mm(Length×Width×Height)/16kg |
| Power supply/power | AC220V±10%,50Hz/100W |
| Wave length range | 190~800nm |
|---|---|
| Baseline noise | ≤±1.0×10-5AU |
| Baseline drift | ≤2.0×10-4AU/h |
| Size/weight | 420×300×175mm(Length×Width×Height)/18kg |
| Power supply/power | AC220V±10%,50Hz/80W |
| Sampling range | 0~100µL(Incremental 0.1µL) |
|---|---|
| Number of samples processed | 120位 |
| Sample residues | <0.01% |
| Sampling repeatability | RSD<0.3%(Full ring injection, 20µL sample ring) |
| Sampling repeatability | RSD<0.5%(Part volume with sample loss injection) |
| Sampling repeatability | RSD<1.0%(Part volume with sample loss injection) |
| Size/weight | 540×400×300mm(Length×Width×Height)/23kg |
| Power supply/power | AC220V±10%,50Hz/30W |
| Temperature control range | Room temperature is above+5~80℃ |
|---|---|
| Room temperature is above+5~80℃ | ≤0.1℃ |
| Size/weight | 420×300×120mm(Length×Width×Height)/7kg |
| Power supply/power | AC220V±10%,50Hz/130W |
| Flow Range | 0.001~10.000mL/min |
|---|---|
| Gradient accuracy | ≤±1.0% |
| Maximum working pressure | 63MPa |
| Retention time repeatability | ≤0.1% |
| Communication method | UDP Network Communication |
| Mixing volume | 750μL |
| Size / Weight | 400×300×180mm(Length×Width×Height)/15kg |
| Power supply/power | AC220V±10%,50Hz/100W |
| Online degassing | Built-in binary quaternary |
|---|---|
| Maximum flow rate of single channel | 10.000mL/min |
| Deaeration fluid channel inner diameter | 1.143mm |
| Standard channel volume | 480μL/channel |
| Contact with liquid materials | PEEK,Teflon® AF |
| Size / Weight | 250×95×155mm(Length×Width×Height)/1.5kg |
| Power supply/power | AC220V±10%,50Hz/20W |
| Flow Range | ≤10mL/min |
|---|---|
| Switching speed | ≤100ms |
| Inner chamber volume | ≤40μL |
| Maximum withstand pressure | 0.3MPa |
| Communication method | UDP |
| Liquid contact material | 316L/PFA/FFKM |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Temperature Control Range of Water Trap: RT~240 ℃, with an increment of 1°C, the heating power is about 100W;; Temperature Control Range of Valve Injection System: RT~220 ℃, with an increment of 1°C, the heating power is about 150W;. Match the analytical method, detector, column and sample-handling configuration.