Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Grating Portable Spectrophotometer, SP-CLR580A,B is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: SP-CLR580A, SP-CLR580B. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | SP-CLR580A | SP-CLR580B |
|---|---|---|
| Optical Geometry | D/8(Diffused lighting, 8 degrees observe angle)、SCI(specular reflection included)/SCE(specular reflection excluded),simultaneous measurement. (conform to CIE No.15、ISO 7724/1、ASTM E1164、DIN 5033 Teil7、 JIS Z8722 Condition c standards) | D/8(Diffused lighting, 8 degrees observe angle)、SCI(specular reflection included)/SCE(specular reflection excluded),simultaneous measurement. (conform to CIE No.15、ISO 7724/1、ASTM E1164、DIN 5033 Teil7、 JIS Z8722 Condition c standards) |
| Integrating Sphere Size | φ40mm, diffused reflection surface coating | φ40mm, diffused reflection surface coating |
| Light Source | CLEDs(entire wavelength balanced LED light source) | CLEDs(entire wavelength balanced LED light source) |
| Sensor | Dual light path sensor array | Dual light path sensor array |
| Wavelength Range | 400-700nm | 400-700nm |
| Wavelength Interval | 10nm | 10nm |
| Half Spectral Width | 5nm | 5nm |
| Measured Reflectance Range | 0-200% | 0-200% |
| Reflectance Resolution | 0.01% | 0.01% |
| Observer Angle | 2°/10° | 2°/10° |
| Illuminant | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF |
| Display | SPD distribution/data,sample’s color values,color difference values/graph, pass/fail results, color error tendency, color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report | SPD distribution/data,sample’s color values,color difference values/graph, pass/fail results, color error tendency, color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report |
| Measuring Time Interval | 2s | 2s |
| Measuring Time | 1s | 1s |
| Color Space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance |
| Color Difference Formula | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00 | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00 |
| Other Colorimetric Index | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI(ASTM D1925,ASTM E313-00,ASTM E313-73);Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, Covering power, force,Opacity, color strength | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI(ASTM D1925,ASTM E313-00,ASTM E313-73);Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, Covering power, force,Opacity, color strength |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% | Light splitting reflectivity:standard deviation within 0.08% |
| Repeatability | Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals), Max.:0.05 | Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals), Max.:0.05 |
| Measuring Aperture | φ10mm | φ4mm, 6mm |
| Inter-instrument Error | ΔE*ab within 0.2(BCRA color charts II, average of the 12 charts) | ΔE*ab within 0.2(BCRA color charts II, average of the 12 charts) |
| Battery | Rechargeable, 10000 continuous tests, 7.4V/6000mAh | Rechargeable, 10000 continuous tests, 7.4V/6000mAh |
| Interface | USB | USB |
| Data Storage | 20000 test results | 20000 test results |
| Illuminant Life Span | 1.5 million measurements in 5 years | 1.5 million measurements in 5 years |
| Screen | True color screen that includes all colors | True color screen that includes all colors |
| Operating Environment | 0~45℃, relative humidity 80% or below( at 35°C ),no condensation | 0~45℃, relative humidity 80% or below( at 35°C ),no condensation |
| Operating Environment | -25℃~55℃,relative humidity 80% or below(at 35°C ),no condensation | -25℃~55℃,relative humidity 80% or below(at 35°C ),no condensation |
| Standard Accessory | DC adapter, Lithium battery, manual, color management software, drive software, electronic manual, color management guide, USB cable, black/white calibration tube, protective cover, spire lamella, portable bag, electronic color charts | DC adapter, Lithium battery, manual, color management software, drive software, electronic manual, color management guide, USB cable, black/white calibration tube, protective cover, spire lamella, portable bag, electronic color charts |
| Optional Accessory | Powder molding device, micro printer, measurement and test report | Powder molding device, micro printer, measurement and test report |
| External Dimension(L*W*H)) | 181*73*112mm | 181*73*112mm |
| Net Weight | About 0.55kg(excluding battery’s weight) | About 0.55kg(excluding battery’s weight) |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Wavelength Range: 400-700nm. Compare measurement range, optical configuration, sample format and software.
Spectrometers & Optical Analysis by Infitek. Compare measurement range, optical configuration, sample format and software.
Wavelength Range: 400-700nm. Compare measurement range, optical configuration, sample format and software.