Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Cooling Biochemical Incubator, ICB-B-L Series is listed in VVON's laboratory incubators & growth chambers range for Bangladesh. Published models: ICB-B80L, ICB-B150L, ICB-B200L, ICB-B250L, ICB-B300L, ICB-B400L. Compare chamber capacity and required temperature, atmosphere, humidity or agitation. For a quotation, send the application, working volume, temperature and atmosphere requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | ICB-B80L | ICB-B150L | ICB-B150L | ICB-B200L | ICB-B200L | ICB-B250L | ICB-B250L | ICB-B300L | ICB-B300L | ICB-B400L | ICB-B400L |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacity (L) | 81 | 160 | 160 | 202 | 202 | 251 | 251 | 304 | 304 | 397 | 397 |
| Circulation Mode | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection |
| Dimension (W*D*H) / Internal (mm) | 400*370*550 | 450*420*850 | 450*420*850 | 450*450*1000 | 450*450*1000 | 480*490*1070 | 480*490*1070 | 520*500*1170 | 520*500*1170 | 580*540*1270 | 580*540*1270 |
| Dimension (W*D*H) / External (mm) | 540*580*1075 | 598*633*1471 | 598*633*1471 | 590*659*1525 | 590*659*1525 | 620*690*1595 | 620*690*1595 | 660*702*1695 | 660*702*1695 | 720*747*1795 | 720*747*1795 |
| Temperature / Range (℃) | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 | -10~65 |
| Temperature / Fluctuation (℃) | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 | ±0.5~±1 |
| Temperature / Uniformity (℃) | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 |
| Temperature / Display accuracy | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| Temperature / Control accuracy | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 | ±0.1 |
| Controller | PID | PID | PID | PID | PID | PID | PID | PID | PID | PID | PID |
| Display | LCD | LCD | LCD | LCD | LCD | LCD | LCD | LCD | LCD | LCD | LCD |
| Shelves | 2 | 2 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Alarm Types | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm | Over-temperature alarm, temperature probe failure alarm |
| Electricity / Voltage / Frequency | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz | 1Ø, 220V/50Hz |
| Electricity / Consumption (W) | 760 | 760 | 860 | 860 | 940 | 940 | 1000 | 1000 | 1100 | 1100 | 1800 |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Laboratory Incubators & Growth Chambers by Infitek. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Laboratory Incubators & Growth Chambers by Infitek. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Laboratory Incubators & Growth Chambers by Infitek. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.