Skip to main content

Infitek Constant Temp. & Humidity Chamber, ICB-H-YH Series

Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Constant Temp. & Humidity Chamber, ICB-H-YH Series

Infitek Constant Temp. & Humidity Chamber, ICB-H-YH Series is listed in VVON's laboratory incubators & growth chambers range for Bangladesh. Published models: ICB-H103YH, ICB-H152YH, ICB-H253YH, ICB-H412YH, ICB-H722YH, ICB-H1022YH. Compare chamber capacity and required temperature, atmosphere, humidity or agitation. For a quotation, send the application, working volume, temperature and atmosphere requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelICB-H103YHICB-H103YHICB-H152YHICB-H152YHICB-H253YHICB-H412YHICB-H412YHICB-H722YHICB-H722YHICB-H1022YHICB-H1022YH
Capacity (L)10310315215225341241272272210221022
Circulation ModeForced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)Forced Convection (Balanced Type)
Dimension (W*D*H) / Internal (mm)480*390*550480*390*550500*460*660500*460*660640*460*860560*530*1390560*530*1390980*530*1390980*530*1390980*750*1390980*750*1390
Dimension (W*D*H) / External (mm)645*700*1255645*700*1255665*780*1360665*780*1360800*780*15701025*810*17351025*810*17351445*810*17351445*810*17351445*1030*17351445*1030*1735
Temperature / Range (℃)-5~70-5~70-5~70-5~70-5~70-5~70-5~70-5~70-5~70-5~70-5~70
Temperature / Resolution (℃)0.10.10.10.10.10.10.10.10.10.10.1
Temperature / Fluctuation (℃)±0.2±0.2±0.2±0.2±0.2±0.2±0.2±0.2±0.2±0.5±0.5
Temperature / Uniformity (℃)±0.5±0.5±0.5±0.5±0.5±0.5±0.5±0.5±0.5±1±1
Humidity / Range15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH15%~95%RH
Humidity / Fluctuation±1%RH±1%RH±1%RH±1%RH±1%RH±1%RH±1%RH±1%RH±1%RH±1.5%RH±1.5%RH
Operating Ambient Temperature (℃)5-305-305-305-305-305-305-305-305-305-305-30
Shelves (Standard)23333344444
Test Hole (mm)φ40φ40φ40φ40φ40φ40φ40φ40φ40φ40φ40
Electricity / Voltage/FrequencyAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50HzAC 220V, 50Hz
Electricity / Consumption (W)13001400140020002000200025002500350035003800
Safety Protection / Refrigeration SystemCompressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.
Safety Protection / OthersMain power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment