Skip to main content

BIOBASE Neonatal Jaundice Therapy Apparatus BHZ-001 BHZ-002

Brand: BIOBASE | Category: Medical Equipment

BIOBASE Neonatal Jaundice Therapy Apparatus BHZ-001 BHZ-002

BIOBASE Neonatal Jaundice Therapy Apparatus BHZ-001 BHZ-002 is listed in VVON's neonatal care equipment range for Bangladesh. Published models: BHZ-001, BHZ-002. Confirm the neonatal-care application, monitoring functions and required accessories. For a quotation, send the care application, required monitoring, accessories and installation location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelBHZ-001BHZ-002
Light SourceLEDLED
Dominant Wavelength of Blue Light(nm)425~475425~475
Lifetime of the LED5000h5000h
Product Service Life6 years6 years
Radiation Therapy Distance(mm)Distance light box 450Distance light box 450
Phototherapy Effective Surface Area(mm)300*200300*200
The Total lrradiance for Maximum Bilirubin on the Effective Surface Area5.2mW/cm^(2)±0.5mW/cm^(2)2.4mW/cm^(2)+0.3mW/cm^(2)
The Total lrradiance on the Effective Surface Area?≥2.5mW/cm^(2)≥1.0mW/cm^(2)
Average Value of the Total lrradiance for Bilirubin4.0mW/cm^(2)±0.5mW/cm^(2)1.5mW/cm^(2)±0.5mW/cm^(2)
Uniformity of the Total lrradiance for Bilirubin>0.4>0.4
Noise≤45dB(A)≤45dB(A)
Light Box lrradiation Angle Adjustment Range0~90° adjusted up and down\
Light Box Height Adjustment Range(mm)1350~1650\
Display Timer Range0~9999hours59minutes0~9999hours59minutes
Ambient Air Movement Rate(m/s)<0.3<0.3
Working Temp.5~35℃5~35℃
Working Relative Humidity30%~80%30%~80%
Working Atmospheric Pressure700~1060hPa700~1060hPa
Overvoltage CategoryIIII
Pollution Grade22
Waterproofing GradeIPXOIPXO
Application Environment Elevation(m)≤3000≤3000
Power SupplyAC100~240V, 50/60HzAC100~240V, 50/60Hz
External Size(W*D*H)705*620*1350~1650mm470*320*65mm
Packing Size(W*D*H)750*710*1250mm615*415*180mm
Net Weight15kg4kg
Gross Weight33kg5.1kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment

View full category