Brand: BIOBASE | Category: Medical Equipment

BIOBASE Infant Incubator BK-3201 is listed in VVON's neonatal care equipment range for Bangladesh. Published models: Type I+, Type I, Type II, Type III, Type IV. Confirm the neonatal-care application, monitoring functions and required accessories. For a quotation, send the care application, required monitoring, accessories and installation location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| General Parameters | Item | Specifications |
|---|---|---|
| General Parameters | Power Supply | AC220V, 50/60Hz(Standard) 1320VA;; AC110V, 60Hz(Optional) |
| General Parameters | Size(L*W*H) | 950*645*(1250~1450)mm |
| General Parameters | Maximum Heater Output Power(220VAC) | Air Chamber Heater: 330W Water Tank Heater: 155W |
| General Parameters | Auxiliary Network Power Output | AC220V/50Hz, both maximum permissible currents are 220V 1.5A |
| General Parameters | Heater Indication | 0~100%, 10% increasing amount |
| General Parameters | Temperature Control Mode | Bed temperature mode; The skin temperature mode |
| General Parameters | Bed Temperature Control Temperature Range | 25.0~37.0℃; 37.1~39.0℃(Span mode) |
| General Parameters | Skin Temperature Control Range | 34.0~37.0℃; 37.1~38.0℃(Span mode) |
| General Parameters | Skin Temperature Sensor Display Range | 5.0~65.0℃ |
| General Parameters | Heating Time | ≤50min |
| General Parameters | Temperature Variability | ≤0.5℃ |
| General Parameters | Temperature Uniformity(Mattress in horizontal position) | ≤0.8℃ |
| General Parameters | Temperature Uniformity(Mattress in tilted position) | ≤1.0℃ |
| General Parameters | Difference Between Average Incubator Temperature and Control Temperature | ≤1.5℃ |
| General Parameters | Skin Temperature Sensor Accuracy | ±0.3℃ |
| Humidity Control | The running time of the tank after it is filled with distilled water | Humidity below 70%RH, at least 24h |
| Humidity Control | Water Tank Capacity | 1500ml |
| Humidity Control | Humidity Display Range | 0%RH~99%RH |
| Humidity Control | Humidity Control Range | CAH%RH~90%RH(1% per adjustment) |
| Humidity Control | Humidity Control Accuracy | ±10% |
| Oxygen Concentration Control | Oxygen Concentration Display Range | 0%~99% |
| Oxygen Concentration Control | Oxygen Concentration Display Resolution | 1% |
| Oxygen Concentration Control | Oxygen Concentration Control Accuracy | ±5% oxygen volume concentration |
| Oxygen Concentration Control | Oxygen Concentration Setting Range | 21%~60%(1% per adjustment) |
| Oxygen Concentration Control | Oxygen Sensor Service Life | The maximum use time is 10000h at 100% oxygen concentration |
| Transport Storage | Temperature | -20℃~+55℃ |
| Transport Storage | Atmospheric Pressure Range | 500hPa~1060hPa |
| Transport Storage | Relative Humidity | ≤93%RH |
| Transport Storage | Packing Size/Gross Weight | 1150*800*1600mm 190kg |
| The Work Environment | Relative Humidity | 30%RH~75%RH |
| The Work Environment | The Environment Temperature | +20℃~+30℃ |
| The Work Environment | Pressure Range | 700hPa~1060hPa |
| The Work Environment | Service Altitude | ≤2000m |
| The Work Environment | Over Voltage Category | II |
| The Work Environment | Pollution Levels | 2 |
| The Work Environment | Ambient Air Velocity | ≤0.3m/s |
| Other Indicators | Environmental Noise In Incubator Baby Compartment | No more than 55dB(A) at stable temperature |
| Other Indicators | Carbon Dioxide Concentration In The Infant Compartment | A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization |
| Other Indicators | The velocity of air flow over a baby's mattress | ≤0.35m/s |
| General Alarm | Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm | Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm |
| The System Alarm | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure |
| Model | Type I+ | Type I | Type II | Type III | Type IV |
|---|---|---|---|---|---|
| Temp. Control | Bed/Skin Temperature | Bed/Skin Temperature | Bed/Skin Temperature | Bed/Skin Temperature | Bed/Skin Temperature |
| Display | LCD | LCD | LCD | LCD | LCD |
| Bed Temp. Control Range | 25℃~39℃ | 25℃~39℃ | 25℃~39℃ | 25℃~39℃ | 25℃~39℃ |
| Skin Temp. Control Range | 34℃~38℃ | 34℃~38℃ | 34℃~38℃ | 34℃~38℃ | / |
| Humidity Control Range | CAH%~99%RH | CAH%~99%RH | CAH%~99%RH | / | / |
| Oxygen Control Range | 21%~99% | 21%~99% | / | / | / |
| Cabinet | Yes | Yes | Yes | Yes | Yes |
| Height Adjustable | Yes; | / | / | / | / |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Neonatal Care Equipment by BIOBASE. Confirm the neonatal-care application, monitoring functions and required accessories.
Volume Range: 0~10L; Volume Accuracy: ≤±3% or ±0.05L(whichever is greater). Confirm the neonatal-care application, monitoring functions and required accessories.
Skin Temp. Control Range: 25~37.5°C; Skin Temp. Display Range: 5~65°C. Confirm the neonatal-care application, monitoring functions and required accessories.