BIOBASE Infant Incubator BK-3201

Brand: BIOBASE | Category: Medical Equipment

BIOBASE Infant Incubator BK-3201

BIOBASE Infant Incubator BK-3201 is listed in VVON's neonatal care equipment range for Bangladesh. Published models: Type I+, Type I, Type II, Type III, Type IV. Confirm the neonatal-care application, monitoring functions and required accessories. For a quotation, send the care application, required monitoring, accessories and installation location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
General ParametersItemSpecifications
General ParametersPower SupplyAC220V, 50/60Hz(Standard) 1320VA;; AC110V, 60Hz(Optional)
General ParametersSize(L*W*H)950*645*(1250~1450)mm
General ParametersMaximum Heater Output Power(220VAC)Air Chamber Heater: 330W Water Tank Heater: 155W
General ParametersAuxiliary Network Power OutputAC220V/50Hz, both maximum permissible currents are 220V 1.5A
General ParametersHeater Indication0~100%, 10% increasing amount
General ParametersTemperature Control ModeBed temperature mode; The skin temperature mode
General ParametersBed Temperature Control Temperature Range25.0~37.0℃; 37.1~39.0℃(Span mode)
General ParametersSkin Temperature Control Range34.0~37.0℃; 37.1~38.0℃(Span mode)
General ParametersSkin Temperature Sensor Display Range5.0~65.0℃
General ParametersHeating Time≤50min
General ParametersTemperature Variability≤0.5℃
General ParametersTemperature Uniformity(Mattress in horizontal position)≤0.8℃
General ParametersTemperature Uniformity(Mattress in tilted position)≤1.0℃
General ParametersDifference Between Average Incubator Temperature and Control Temperature≤1.5℃
General ParametersSkin Temperature Sensor Accuracy±0.3℃
Humidity ControlThe running time of the tank after it is filled with distilled waterHumidity below 70%RH, at least 24h
Humidity ControlWater Tank Capacity1500ml
Humidity ControlHumidity Display Range0%RH~99%RH
Humidity ControlHumidity Control RangeCAH%RH~90%RH(1% per adjustment)
Humidity ControlHumidity Control Accuracy±10%
Oxygen Concentration ControlOxygen Concentration Display Range0%~99%
Oxygen Concentration ControlOxygen Concentration Display Resolution1%
Oxygen Concentration ControlOxygen Concentration Control Accuracy±5% oxygen volume concentration
Oxygen Concentration ControlOxygen Concentration Setting Range21%~60%(1% per adjustment)
Oxygen Concentration ControlOxygen Sensor Service LifeThe maximum use time is 10000h at 100% oxygen concentration
Transport StorageTemperature-20℃~+55℃
Transport StorageAtmospheric Pressure Range500hPa~1060hPa
Transport StorageRelative Humidity≤93%RH
Transport StoragePacking Size/Gross Weight1150*800*1600mm 190kg
The Work EnvironmentRelative Humidity30%RH~75%RH
The Work EnvironmentThe Environment Temperature+20℃~+30℃
The Work EnvironmentPressure Range700hPa~1060hPa
The Work EnvironmentService Altitude≤2000m
The Work EnvironmentOver Voltage CategoryII
The Work EnvironmentPollution Levels2
The Work EnvironmentAmbient Air Velocity≤0.3m/s
Other IndicatorsEnvironmental Noise In Incubator Baby CompartmentNo more than 55dB(A) at stable temperature
Other IndicatorsCarbon Dioxide Concentration In The Infant CompartmentA mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization
Other IndicatorsThe velocity of air flow over a baby's mattress≤0.35m/s
General AlarmPower failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarmPower failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm
The System AlarmMcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failureMcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure
Manufacturer specifications 2
ModelType I+Type IType IIType IIIType IV
Temp. ControlBed/Skin TemperatureBed/Skin TemperatureBed/Skin TemperatureBed/Skin TemperatureBed/Skin Temperature
DisplayLCDLCDLCDLCDLCD
Bed Temp. Control Range25℃~39℃25℃~39℃25℃~39℃25℃~39℃25℃~39℃
Skin Temp. Control Range34℃~38℃34℃~38℃34℃~38℃34℃~38℃/
Humidity Control RangeCAH%~99%RHCAH%~99%RHCAH%~99%RH//
Oxygen Control Range21%~99%21%~99%///
CabinetYesYesYesYesYes
Height AdjustableYes;////

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment

View full category