Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Ducted PP Fume Hood FH(P) is listed in VVON's fume hoods & laboratory ventilation range for Bangladesh. Published models: FH1000(P), FH1200(P), FH1500(P), FH1800(P). Check chemical compatibility, extraction method, working space and ducting needs. For a quotation, send the chemicals, process, hood width, extraction route and room utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | FH1000(P) | FH1200(P) | FH1500(P) | FH1800(P) |
|---|---|---|---|---|
| External Size(W*D*H) | 1047*800*2450mm | 1247*800*2450mm | 1547*800*2450mm | 1847*800*2450mm |
| Internal Size(W*D*H) | 787*560*700mm | 987*560*700mm | 1287*560*700mm | 1587*560*700mm |
| Work Surface Height | 820mm | 820mm | 820mm | 820mm |
| Max Opening | 740mm | 740mm | 740mm | 740mm |
| Air Velocity | 0.3~0.8m/s | 0.3~0.8m/s | 0.3~0.8m/s | 0.3~0.8m/s |
| Noise | ≤68dB | ≤68dB | ≤68dB | ≤68dB |
| Exhaust Duct | 5 meters, Φ250mm | 5 meters, Φ250mm | 5 meters, Φ250mm | 5 meters, Φ250mm |
| LED Lamp | 9W*2 | 12W*2 | 15W*2 | 20W*2 |
| Blower | Built-in PP centrifugal blower(2 blowers for FH1800(P) only), Speed adjustable | Built-in PP centrifugal blower(2 blowers for FH1800(P) only), Speed adjustable | Built-in PP centrifugal blower(2 blowers for FH1800(P) only), Speed adjustable | Built-in PP centrifugal blower(2 blowers for FH1800(P) only), Speed adjustable |
| Front Window | Resistant to acid and alkali, manual, 5mm toughened glass, height adjustable | Resistant to acid and alkali, manual, 5mm toughened glass, height adjustable | Resistant to acid and alkali, manual, 5mm toughened glass, height adjustable | Resistant to acid and alkali, manual, 5mm toughened glass, height adjustable |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
| Consumption | 400W | 400W | 500W | 700W |
| Material / Main Body | Made of porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion. | Made of porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion. | Made of porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion. | Made of porcelain white PP, thickness 8mm, resistant to strong acid, alkali and anti-corrosion. |
| Material / Work Table | Chemical resistant phenolic resin | Chemical resistant phenolic resin | Chemical resistant phenolic resin | Chemical resistant phenolic resin |
| Standard Accessory | LED light Work table: chemical resistant phenolic resin 5 meters PVC duct(2pcs of 4.3 meters PVC dust for FH1800(P) only), Diameter: 250mm Pipe strap*2(4pcs for FH1800(P) only) RVV power cord(3*1.0mm²*3000mm) Base cabinet Waterproof socket*2 Tail insert Water tap(PP) Gas tap(PP) Water sink PP centrifugal blower*1(2 for FH1800(P) only) | LED light Work table: chemical resistant phenolic resin 5 meters PVC duct(2pcs of 4.3 meters PVC dust for FH1800(P) only), Diameter: 250mm Pipe strap*2(4pcs for FH1800(P) only) RVV power cord(3*1.0mm²*3000mm) Base cabinet Waterproof socket*2 Tail insert Water tap(PP) Gas tap(PP) Water sink PP centrifugal blower*1(2 for FH1800(P) only) | LED light Work table: chemical resistant phenolic resin 5 meters PVC duct(2pcs of 4.3 meters PVC dust for FH1800(P) only), Diameter: 250mm Pipe strap*2(4pcs for FH1800(P) only) RVV power cord(3*1.0mm²*3000mm) Base cabinet Waterproof socket*2 Tail insert Water tap(PP) Gas tap(PP) Water sink PP centrifugal blower*1(2 for FH1800(P) only) | LED light Work table: chemical resistant phenolic resin 5 meters PVC duct(2pcs of 4.3 meters PVC dust for FH1800(P) only), Diameter: 250mm Pipe strap*2(4pcs for FH1800(P) only) RVV power cord(3*1.0mm²*3000mm) Base cabinet Waterproof socket*2 Tail insert Water tap(PP) Gas tap(PP) Water sink PP centrifugal blower*1(2 for FH1800(P) only) |
| Optional Accessory | PP work table, epoxy resin board or ceramic board Active carbon filter Outer PP centrifugal blower *1 (2 for FH1800(P) only); Splicable base cabinet(only not for FH1800(P)) | PP work table, epoxy resin board or ceramic board Active carbon filter Outer PP centrifugal blower *1 (2 for FH1800(P) only); Splicable base cabinet(only not for FH1800(P)) | PP work table, epoxy resin board or ceramic board Active carbon filter Outer PP centrifugal blower *1 (2 for FH1800(P) only); Splicable base cabinet(only not for FH1800(P)) | PP work table, epoxy resin board or ceramic board Active carbon filter Outer PP centrifugal blower *1 (2 for FH1800(P) only); Splicable base cabinet(only not for FH1800(P)) |
| Gross Weight / Main Body | 137kg | 155kg | 180kg | 206kg |
| Gross Weight / Base Cabinet | 89kg or 80kg(Splicable) | 99kg or 90kg(Splicable) | 114kg or 102kg(Splicable) | 140kg |
| Package Size(W*D*H) / Main Body | 1188*938*1612mm | 1388*938*1612mm | 1688*938*1612mm | 1988*938*1612mm |
| Package Size(W*D*H) / Base Cabinet | 1188*888*1000mm or 1200*1000*450mm(Splicable) | 1388*888*1000mm or 1400*1000*450mm(Splicable) | 1688*888*1000mm or 1700*1000*450mm(Splicable) | 1988*888*1000mm |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Fume Hoods & Laboratory Ventilation by BIOBASE. Check chemical compatibility, extraction method, working space and ducting needs.
Fume Hoods & Laboratory Ventilation by BIOBASE. Check chemical compatibility, extraction method, working space and ducting needs.
System Exhaust Volume: 840m³/h. Check chemical compatibility, extraction method, working space and ducting needs.