BIOBASE 5-Part Hematology Analyzer BK-6500

Brand: BIOBASE | Category: Medical Equipment

BIOBASE 5-Part Hematology Analyzer BK-6500

BIOBASE 5-Part Hematology Analyzer BK-6500 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: BK-6500. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelBK-6500BK-6500BK-6500BK-6500
Throughput70 tests/hour70 tests/hour70 tests/hour70 tests/hour
Assay Items5 parts, 25 parameters, 3 histograms(WBC/BASO, RBC, PLT), 3D scattergram5 parts, 25 parameters, 3 histograms(WBC/BASO, RBC, PLT), 3D scattergram5 parts, 25 parameters, 3 histograms(WBC/BASO, RBC, PLT), 3D scattergram5 parts, 25 parameters, 3 histograms(WBC/BASO, RBC, PLT), 3D scattergram
PrincipleTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test
Test ModeCBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and PredilutedCBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and PredilutedCBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and PredilutedCBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted
Sample VolumeCBC+DIFF mode: ≤20μl CBC mode: ≤10μlCBC+DIFF mode: ≤20μl CBC mode: ≤10μlCBC+DIFF mode: ≤20μl CBC mode: ≤10μlCBC+DIFF mode: ≤20μl CBC mode: ≤10μl
Parameters25 reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 6 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#25 reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 6 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#25 reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 6 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#25 reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 6 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#
PerformanceItemLinearity RangeCarry OverCV
PerformanceWBC0~300.0*10^9/L≤0.5%≤2.0%
PerformanceRBC0~8.00*10^12/L≤0.5%≤1.5%
PerformanceHGB0~260g/L≤0.5%≤1.5%
PerformancePLT0~3000*10^9/L≤1.0%≤4.0%
StorageUp to 300,000 results including histograms, scattergrams and patient informationUp to 300,000 results including histograms, scattergrams and patient informationUp to 300,000 results including histograms, scattergrams and patient informationUp to 300,000 results including histograms, scattergrams and patient information
Display14 inch touch screen, resolution 1366*76814 inch touch screen, resolution 1366*76814 inch touch screen, resolution 1366*76814 inch touch screen, resolution 1366*768
Interface4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader
SystemLINUS systemLINUS systemLINUS systemLINUS system
Loading Position50 sample positions50 sample positions50 sample positions50 sample positions
Power SupplyAC100~240V, 50/60Hz; 300VAAC100~240V, 50/60Hz; 300VAAC100~240V, 50/60Hz; 300VAAC100~240V, 50/60Hz; 300VA
Package Size(W*D*H)Main Machine: 725*665*700mm Accessories: 950*500*580mmMain Machine: 725*665*700mm Accessories: 950*500*580mmMain Machine: 725*665*700mm Accessories: 950*500*580mmMain Machine: 725*665*700mm Accessories: 950*500*580mm
Gross WeightMain Machine: 60kg Accessories: 27.6kgMain Machine: 60kg Accessories: 27.6kgMain Machine: 60kg Accessories: 27.6kgMain Machine: 60kg Accessories: 27.6kg
Reagent Package Size(W*D*H)330*330*330mm; 330*230*230mm; 330*230*230mm330*330*330mm; 330*230*230mm; 330*230*230mm330*330*330mm; 330*230*230mm; 330*230*230mm330*330*330mm; 330*230*230mm; 330*230*230mm
Reagent Gross Weight22kg, 2kg, 1kg22kg, 2kg, 1kg22kg, 2kg, 1kg22kg, 2kg, 1kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment