Brand: BIOBASE | Category: Medical Equipment

BIOBASE 5-Part Hematology Analyzer BK-6310 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: BK-6310. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-6310 | BK-6310 | BK-6310 | BK-6310 |
|---|---|---|---|---|
| Throughput | 60 Tests/hour | 60 Tests/hour | 60 Tests/hour | 60 Tests/hour |
| Assay Items | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram |
| Principle | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test |
| Test Mode | CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted | CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted | CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted | CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted |
| Sample Volume | CBC+DIFF mode: ≤20μl CBC mode: ≤10μl | CBC+DIFF mode: ≤20μl CBC mode: ≤10μl | CBC+DIFF mode: ≤20μl CBC mode: ≤10μl | CBC+DIFF mode: ≤20μl CBC mode: ≤10μl |
| Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 4 research parameters: ALY%, ALY#, LIC%, LIC# |
| Performance | Item | Linearity Range | Carry Over | CV |
| Performance | WBC | 1~99.9*10^(9)/L | ≤0.5% | ≤2.0% |
| Performance | RBC | 0.3~7*10^(12)/L | ≤0.5% | ≤1.5% |
| Performance | HGB | 20~240g/L | ≤0.5% | ≤1.5% |
| Performance | PLT | 20~999*10^(9)/L | ≤1.0% | ≤4.0% |
| Storage | 300,000 results including histogram, scattergram and patient information | 300,000 results including histogram, scattergram and patient information | 300,000 results including histogram, scattergram and patient information | 300,000 results including histogram, scattergram and patient information |
| Interface | 4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader |
| System | LINUS system | LINUS system | LINUS system | LINUS system |
| Power Supply | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA |
| Package Size(W*D*H) | 575*490*690mm | 575*490*690mm | 575*490*690mm | 575*490*690mm |
| Gross Weight | 46kg | 46kg | 46kg | 46kg |
| Reagent Package Size(W*D*H) | 330*330*330mm; 330*230*230mm; 330*230*230mm | 330*330*330mm; 330*230*230mm; 330*230*230mm | 330*330*330mm; 330*230*230mm; 330*230*230mm | 330*330*330mm; 330*230*230mm; 330*230*230mm |
| Reagent Gross Weight | 22kg, 2kg, 1kg | 22kg, 2kg, 1kg | 22kg, 2kg, 1kg | 22kg, 2kg, 1kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by BIOBASE. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.