Brand: EDIBON | Category: Scientific & Laboratory Equipment
Two chamber plant in which the circuit branches after the accumulator so a refrigeration chamber and a freezing chamber can run separately or together. An evaporation pressure regulator holds the refrigeration chamber at a higher pressure than the freezing chamber.
| Parameter | Value |
|---|---|
| Specification | Solenoid valves allow individual or parallel operation of the two chamber evaporators |
| Specification | Evaporation pressure regulator sets a higher evaporating pressure in the refrigeration chamber |
| Specification | Heat exchanger before expansion for refrigerant subcooling |
| Specification | Electric heating element in the freezing chamber for defrosting |
| Specification | Pressure sensors, manometers, temperature sensors and flow sensor at each stage |
| Specification | Pressure switch between compressor inlet and outlet stops the process at hazardous pressures |