Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Zeta Potential and Nano Particle Size Analyzer, PSA-LS901 is listed in VVON's particle size rheology & physical analysis range for Bangladesh. Published models: PSA-LS901. Match the material, property, measurement range and sample-preparation method. For a quotation, send the material, property to measure, measurement range and sample preparation. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | PSA-LS901 | PSA-LS901 | PSA-LS901 | PSA-LS901 |
|---|---|---|---|---|
| Measurement Range | 0.3-10000nm (sample dependent) | 0.3-10000nm (sample dependent) | -500mV to +500mV | -500mV to +500mV |
| Concentration Range | 0.1 mg/mL-100 mg/mL (sample dependent) | 0.1 mg/mL-100 mg/mL (sample dependent) | 0.1 mg/mL-100 mg/mL (sample dependent) | 0.1 mg/mL-100 mg/mL (sample dependent) |
| Electrophoretic Mobility Range | > ±20 μm·cm/(V·s) | > ±20 μm·cm/(V·s) | > ±20 μm·cm/(V·s) | > ±20 μm·cm/(V·s) |
| Maximum Conductivity | 200 mS/cm (sample dependent) | 200 mS/cm (sample dependent) | 200 mS/cm (sample dependent) | 200 mS/cm (sample dependent) |
| Accuracy Error | <1% (National standard sample D50 value) | <1% (National standard sample D50 value) | <15% (Standard sample) | <15% (Standard sample) |
| Repeatability Error | <1% (National standard sample D50 value) | <1% (National standard sample D50 value) | <15%(Standard sample) | <15%(Standard sample) |
| Laser Source | Semiconductor laser, λ = 635 nm, P = 1- 40 mW (adjustable) | Semiconductor laser, λ = 635 nm, P = 1- 40 mW (adjustable) | Semiconductor laser, λ = 635 nm, P = 1- 40 mW (adjustable) | Semiconductor laser, λ = 635 nm, P = 1- 40 mW (adjustable) |
| Detector | Photomultiplier tube | Photomultiplier tube | Photomultiplier tube | Photomultiplier tube |
| Scattering Angle | 90° | 90° | 18° | 18° |
| Sample Cell Volume | 10 mm*10 mm*40 mm, 1-4mL | 10 mm*10 mm*40 mm, 1-4mL | 10 mm*10 mm*60 mm, 1mL | 10 mm*10 mm*60 mm, 1mL |
| Temperature Control Range | 5-90 °C | 5-90 °C | 5-90 °C | 5-90 °C |
| Temperature Control Accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ |
| Test Speed | <5 min | <5 min | <5 min | <5 min |
| Measured Parameters | Nanoparticle size distribution, Zeta potential | Nanoparticle size distribution, Zeta potential | Nanoparticle size distribution, Zeta potential | Nanoparticle size distribution, Zeta potential |
| Digital Correlator | Model | HA1024 | HA1024 | HA1024 |
| Digital Correlator | Auto-correlation Channels | 892 | 892 | 892 |
| Digital Correlator | Baseline Channels | 4 | 4 | — |
| Digital Correlator | Physical Channels | 5000 | 5000 | — |
| Digital Correlator | Unit Delay Time | 1µs-10ms (adjustable) | 1µs-10ms (adjustable) | 1µs-10ms (adjustable) |
| External Dimensions | 560 mm*450 mm*300 mm | 560 mm*450 mm*300 mm | 560 mm*450 mm*300 mm | 560 mm*450 mm*300 mm |
| Net Weight | 20kg | 20kg | 20kg | 20kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by BIOBASE. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.