Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Potentiometric Titrator, TITR-A51 is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: TITR-A51. Published details include Temp. Compensation / Range: (-10.0~135.0)℃. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | TITR-A51 |
|---|---|
| Repeatability | ≤0.2% |
| Burette / Accuracy | 5mL Burette: ±0.010mL; 10mL Burette: ±0.020mL; 20mL Burette: ±0.030mL |
| Burette / Resolution | 1/480000 |
| Measuring Unit / Range | (-2000.00~2000.00)mV; (-5.000~20.000)pH; pX: (-2.000~20.000)pX; Ion: (1.000e-9~9.999e+9)μg/L, mg/L, g/L, mol/L, mmol/L, ppm, ppb |
| Measuring Unit / Resolution | pH: 0.001pH; pX: 0.001pX; Ion: Up to 4 significant digits; mV: 0.01mV |
| Measuring Unit / Accuracy | pH: ±0.002pH; mV: ±0.03% or ±0.2mV |
| Measuring Unit / Fluctuation | ±0.3mV/3h |
| Measuring Unit / Repeatability | ≤0.1mV |
| Temp. Compensation / Range | (-10.0~135.0)℃ |
| Temp. Compensation / Resolution | 0.1℃ |
| Temp. Compensation / Accuracy | ±0.1℃ |
| General / Power Supply | AC 80~250V, 47~63Hz |
| General / Dimensions | 240×370×270mm |
| General / Net Weight | About 4kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temp. Compensation / Range: (-5.0~110.0)℃. Match sample matrix, measurement method, concentration range and reagent needs.
Moisture Analysis & Titration by Infitek. Match sample matrix, measurement method, concentration range and reagent needs.
Moisture Analysis & Titration by Infitek. Match sample matrix, measurement method, concentration range and reagent needs.