Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Moisture Content Tester, MCA110-T Series is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: MCA110-T10E, MCA110-T5E, MCA110-T1E. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Heating Mode Setting | Stop Mode Setting | Heating Temp. Setting |
|---|---|---|
| Heating Time Setting | Baud Rate Setting | Language (CN/EN) Setting |
| Date & Time Setting | Data Storage Setting | Factory Reset |
| Instrument Calibration | Empty Pan Preheating |
| Model | MCA110-T10E | MCA110-T5E | MCA110-T1E |
|---|---|---|---|
| Max. Capacity | 110g | 110g | 110g |
| Readability | 0.01g | 0.005g | 0.001g |
| Sensor | Load cell | Load cell | Load cell |
| Pan Size | φ100mm | φ100mm | φ100mm |
| Display | 5-inch full-color touch screen | 5-inch full-color touch screen | 5-inch full-color touch screen |
| Operating Temperature | 15℃~30℃ | 15℃~30℃ | 15℃~30℃ |
| Heat Source | Halogen lamp | Halogen lamp | Halogen lamp |
| Temp. Sensor | PT100 | PT100 | PT100 |
| Temp. Range | 40°C~160°C (1°C step) | 40°C~160°C (1°C step) | 40°C~160°C (1°C step) |
| Time Setting | 1~99min (10s step) | 1~99min (10s step) | 1~99min (10s step) |
| Moisture Range | 0.00%~100.00% | 0.00%~100.00% | 0.00%~100.00% |
| Moisture Readability | 0.10% | 0.05% | 0.01% |
| Solid Content Range | 100.00%~0.00% | 100.00%~0.00% | 100.00%~0.00% |
| Solid Content Readability | 0.10% | 0.05% | 0.01% |
| Data Storage | 20 Groups | 20 Groups | 20 Groups |
| Real-time Curve | Real-time dynamic curve | Real-time dynamic curve | Real-time dynamic curve |
| Testing Space | 30mm | 30mm | 30mm |
| Electricity | 220V, 50Hz / 110V, 60Hz | 220V, 50Hz / 110V, 60Hz | 220V, 50Hz / 110V, 60Hz |
| External Dimensions | 340*215*170mm | 340*215*170mm | 340*215*170mm |
| Package Dimensions | 415*310*255mm | 415*310*255mm | 415*310*255mm |
| N.W./G.W. | 4.0kg/3.5kg | 4.0kg/3.5kg | 4.0kg/3.5kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Measurement Range: 3%~35%; Ambient Temperature Range: 0~40℃. Match sample matrix, measurement method, concentration range and reagent needs.
Temp. Compensation / Range: (-5.0~110.0)℃. Match sample matrix, measurement method, concentration range and reagent needs.
Display Measurement Range: 0.1μg water—9999.9999mg water. Match sample matrix, measurement method, concentration range and reagent needs.