Infitek POCT Immunofluorescence Quantitative Analyzer, IFA-S1000

Brand: Infitek | Category: Medical Equipment

Infitek POCT Immunofluorescence Quantitative Analyzer, IFA-S1000 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: IFA-S1000. Published details include Wavelength Range: 740nm. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
ModelIFA-S1000
Test ItemThe product is used cooperatively with immunofluorescence assay kit produced by our company.
Excitation Light SourceLED
Wavelength Range740nm
Test Item ParameterThe user can read configuration parameters of the instrument from information card.
Sample TypeWhole blood, serum, plasma, urine and faeces (subject to specification of immunofluorescence assay kit)
Delay TestDelay test time can be set. Place test card in the instrument and test at fixed time after completion of reaction
Test Speed240 times/hour
Background NumberFluorescence value should be ≤5
RepeatabilityThe variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0%
StabilityThe relative deviation between the test result at 4th hour and the 8th hour after the instrument is working stably and the test result when the instrument just works stably is limited to ±3.0%.
AccuracyWhen the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%.
Measuring TimeThe time from inserting the fluorescence test card to displaying the test result should not exceed 15s.
Linearity RangeWithin the concentration range of standards no less than two orders of magnitudes, the linearly dependent coefficient of the fluorescence value and concentration read by the instrument r≥0.990
ElectricityAC 100V-240V 50Hz/60Hz; Host: DC12V 5A
Input Power60 VA
Dimension200*300*140mm
Net Weight2.0kg
Manufacturer specifications 2
BiomarkersProduct ItemSpecimenReaction TimeMeasuring RangeClinical RangeIntended Use
CardiaccTnlWB/Serum/Plasma12min.0.1-40ng/mL<0.3ng/mLSeveral heart diseases including myocardial infarction and heart failure.
MyoWB/Serum/Plasma12min.5-400ng/mL<58ng/mLAcute myocardial infarction (AMI) in early stage.
CK-MBWB/Serum/Plasma12min.1-200ng/mL<5ng/mLAcute myocardial infarction (AMI) in early stage.
NT-proBNPWB/Serum/Plasma10min.20-35000pg/mLUnder75:0~347pg/mL; Over75:0~449pg/mLHeart failure.
D-DimerWB/Plasma10min.40-10000ng/mL<500ng/mLDisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction,etc.
cTnl+Myo+ CKMBWB/Serum/Plasma12min.Same with single itemSame with single itemTriple marker of myocardial infarction.
ST2WB/Serum/Plasma10min.10-400ng/mL<35ng/mLHeart failure.
Lp-PLA2WB/Serum/Plasma10min.10-900ng/mL<175ng/mLRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
H-FABPWB/Serum/Plasma10min.2.5-160ng/mL<5ng/mLAcute myocardial infarction (AMl) in early stage.
HCYWB/Serum/Plasma15min.1-50μmol/L5-15μmol/LAtherosclerosis, venous embolism, coronary heart disease.
InflammationCRP/hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L; hs-CRP<1mg/LNonspecficity inflammatory marker.
SAAWB/Serum5min.1-200mg/L<10mg/LInflammation &infection.
PCTWB/Serum/Plasma10min.0.2-100ng/mL<0.5ng/mLSepsis.
CRP+SAAWB/Serum/Plasma5min.Same with single itemSame with single itemInflammation &infection.
IL-6WB/Serum/Plasma10min.5-4000pg/mL10pg/mLDiabetes, rheumatoid arthritis,etc.
CalprotectinFecal specimens10min.5-1000mg/g<50mg/gEnteritis.
Thyroid HormoneTSHWB/Serum/Plasma15min.0.3-100mU/L0.3-4.2mU/LHyperthyroidism and hypothyroidism.
T3WB/Serum/Plasma15min.0.5-10nmol/L1.23-3.07nmol/LThyroid dysfunction.
Tπ4WB/Serum/Plasma15min.5-300nmol/L66-181nmol/LThyroid dysfunction.
FT3WB/Serum/Plasma15min.1-50pmol/L3.1-6.8pmol/LThyroid dysfunction.
FT4WB/Serum/Plasma15min.5-100pmol/L12-22pmol/LThyroid dysfunction.
Tumor MakerAFPWB/Serum/Plasma10min.2.5-200ng/mL<20ng/mLPregnancy cancer.
CEAWB/Serum/Plasma10min.1-200ng/mL<5ng/mLColon cancer, colorectal cancer,etc.
NSEWB/Serum/Plasma10min.1-400ng/mL<16ng/mLNon-small cell lung cancer.
FOBFecal specimens10min.50-1000ng/mL<100ng/mLAbnormal recessive gastrointestinal bleeding.
PGIⅡIWB/Serum/Plasma10min.1-100ug/LPGI/PGII>3.0Gastric abnormalities.
PGIWB/Serum/Plasma10min.2.5-200ug/L>70ng/mLGastric abnormalities.
TPSAWB/Serum/Plasma10min.0.5-40ng/mL<4ng/mLProstate cancer.
FPSAWB/Serum/Plasma10min.0.1-10ng/mL<1ng/mLProstate cancer.
CA12-5WB/Serum/Plasma10min.20-500U/mL<35U/mLOvarian cancer.
CA15-3WB/Serum/Plasma10min.10-400U/mL<25U/mLBreast cancer.
HE4WB/Serum/Plasma10min.50-2000pmol/L<140pmol/LOvarian cancer.
CA19-9WB/Serum/Plasma10min.10-400U/mL<27U/mLPancreatic cancer.
HCGWB/Serum/Plasma10min.5-400mIU/mL<10mIU/mLEarly pregnancy, ectopic HCG cancer, incomplete abortion.
CK19 (Cyfra21-1)WB/Serum/Plasma10min.1-100ng/mL<3.3ng/mLNon-small cell lung cancer.

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment

View full category