Brand: Infitek | Category: Medical Equipment
Infitek POCT Immunofluorescence Quantitative Analyzer, IFA-S1000 is listed in VVON's clinical analysers & diagnostics range for Bangladesh. Published models: IFA-S1000. Published details include Wavelength Range: 740nm. Compare the test menu, samples per day, reagent compatibility and quality-control workflow. For a quotation, send the test menu, daily sample volume, reagent requirements and laboratory location. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | IFA-S1000 |
|---|---|
| Test Item | The product is used cooperatively with immunofluorescence assay kit produced by our company. |
| Excitation Light Source | LED |
| Wavelength Range | 740nm |
| Test Item Parameter | The user can read configuration parameters of the instrument from information card. |
| Sample Type | Whole blood, serum, plasma, urine and faeces (subject to specification of immunofluorescence assay kit) |
| Delay Test | Delay test time can be set. Place test card in the instrument and test at fixed time after completion of reaction |
| Test Speed | 240 times/hour |
| Background Number | Fluorescence value should be ≤5 |
| Repeatability | The variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0% |
| Stability | The relative deviation between the test result at 4th hour and the 8th hour after the instrument is working stably and the test result when the instrument just works stably is limited to ±3.0%. |
| Accuracy | When the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%. |
| Measuring Time | The time from inserting the fluorescence test card to displaying the test result should not exceed 15s. |
| Linearity Range | Within the concentration range of standards no less than two orders of magnitudes, the linearly dependent coefficient of the fluorescence value and concentration read by the instrument r≥0.990 |
| Electricity | AC 100V-240V 50Hz/60Hz; Host: DC12V 5A |
| Input Power | 60 VA |
| Dimension | 200*300*140mm |
| Net Weight | 2.0kg |
| Biomarkers | Product Item | Specimen | Reaction Time | Measuring Range | Clinical Range | Intended Use |
|---|---|---|---|---|---|---|
| Cardiac | cTnl | WB/Serum/Plasma | 12min. | 0.1-40ng/mL | <0.3ng/mL | Several heart diseases including myocardial infarction and heart failure. |
| Myo | WB/Serum/Plasma | 12min. | 5-400ng/mL | <58ng/mL | Acute myocardial infarction (AMI) in early stage. | |
| CK-MB | WB/Serum/Plasma | 12min. | 1-200ng/mL | <5ng/mL | Acute myocardial infarction (AMI) in early stage. | |
| NT-proBNP | WB/Serum/Plasma | 10min. | 20-35000pg/mL | Under75:0~347pg/mL; Over75:0~449pg/mL | Heart failure. | |
| D-Dimer | WB/Plasma | 10min. | 40-10000ng/mL | <500ng/mL | Disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction,etc. | |
| cTnl+Myo+ CKMB | WB/Serum/Plasma | 12min. | Same with single item | Same with single item | Triple marker of myocardial infarction. | |
| ST2 | WB/Serum/Plasma | 10min. | 10-400ng/mL | <35ng/mL | Heart failure. | |
| Lp-PLA2 | WB/Serum/Plasma | 10min. | 10-900ng/mL | <175ng/mL | Risk evaluation of ACS and atherosclerotic ischemic stroke patients. | |
| H-FABP | WB/Serum/Plasma | 10min. | 2.5-160ng/mL | <5ng/mL | Acute myocardial infarction (AMl) in early stage. | |
| HCY | WB/Serum/Plasma | 15min. | 1-50μmol/L | 5-15μmol/L | Atherosclerosis, venous embolism, coronary heart disease. | |
| Inflammation | CRP/hs-CRP | WB/Serum/Plasma | 3min. | 0.5-200mg/L | CRP<10mg/L; hs-CRP<1mg/L | Nonspecficity inflammatory marker. |
| SAA | WB/Serum | 5min. | 1-200mg/L | <10mg/L | Inflammation &infection. | |
| PCT | WB/Serum/Plasma | 10min. | 0.2-100ng/mL | <0.5ng/mL | Sepsis. | |
| CRP+SAA | WB/Serum/Plasma | 5min. | Same with single item | Same with single item | Inflammation &infection. | |
| IL-6 | WB/Serum/Plasma | 10min. | 5-4000pg/mL | 10pg/mL | Diabetes, rheumatoid arthritis,etc. | |
| Calprotectin | Fecal specimens | 10min. | 5-1000mg/g | <50mg/g | Enteritis. | |
| Thyroid Hormone | TSH | WB/Serum/Plasma | 15min. | 0.3-100mU/L | 0.3-4.2mU/L | Hyperthyroidism and hypothyroidism. |
| T3 | WB/Serum/Plasma | 15min. | 0.5-10nmol/L | 1.23-3.07nmol/L | Thyroid dysfunction. | |
| Tπ4 | WB/Serum/Plasma | 15min. | 5-300nmol/L | 66-181nmol/L | Thyroid dysfunction. | |
| FT3 | WB/Serum/Plasma | 15min. | 1-50pmol/L | 3.1-6.8pmol/L | Thyroid dysfunction. | |
| FT4 | WB/Serum/Plasma | 15min. | 5-100pmol/L | 12-22pmol/L | Thyroid dysfunction. | |
| Tumor Maker | AFP | WB/Serum/Plasma | 10min. | 2.5-200ng/mL | <20ng/mL | Pregnancy cancer. |
| CEA | WB/Serum/Plasma | 10min. | 1-200ng/mL | <5ng/mL | Colon cancer, colorectal cancer,etc. | |
| NSE | WB/Serum/Plasma | 10min. | 1-400ng/mL | <16ng/mL | Non-small cell lung cancer. | |
| FOB | Fecal specimens | 10min. | 50-1000ng/mL | <100ng/mL | Abnormal recessive gastrointestinal bleeding. | |
| PGIⅡI | WB/Serum/Plasma | 10min. | 1-100ug/L | PGI/PGII>3.0 | Gastric abnormalities. | |
| PGI | WB/Serum/Plasma | 10min. | 2.5-200ug/L | >70ng/mL | Gastric abnormalities. | |
| TPSA | WB/Serum/Plasma | 10min. | 0.5-40ng/mL | <4ng/mL | Prostate cancer. | |
| FPSA | WB/Serum/Plasma | 10min. | 0.1-10ng/mL | <1ng/mL | Prostate cancer. | |
| CA12-5 | WB/Serum/Plasma | 10min. | 20-500U/mL | <35U/mL | Ovarian cancer. | |
| CA15-3 | WB/Serum/Plasma | 10min. | 10-400U/mL | <25U/mL | Breast cancer. | |
| HE4 | WB/Serum/Plasma | 10min. | 50-2000pmol/L | <140pmol/L | Ovarian cancer. | |
| CA19-9 | WB/Serum/Plasma | 10min. | 10-400U/mL | <27U/mL | Pancreatic cancer. | |
| HCG | WB/Serum/Plasma | 10min. | 5-400mIU/mL | <10mIU/mL | Early pregnancy, ectopic HCG cancer, incomplete abortion. | |
| CK19 (Cyfra21-1) | WB/Serum/Plasma | 10min. | 1-100ng/mL | <3.3ng/mL | Non-small cell lung cancer. |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Clinical Analysers & Diagnostics by Infitek. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Sample Volume: Whole blood and peripheral blood: 10μL; Prediluted: 20μL. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.
Clinical Analysers & Diagnostics by Infitek. Compare the test menu, samples per day, reagent compatibility and quality-control workflow.