Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Karl Fischer Titrator, TITR-K5 is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: TITR-K5. Published details include Display Measurement Range: 0.1μg water—9999.9999mg water. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | TITR-K5 |
|---|---|
| Measurement Method | Karl Fischer Coulomb Method |
| Display Measurement Range | 0.1μg water—9999.9999mg water |
| Water Content Range | 0.0000001%-100% (the min. resolution of the printed result is 0.0001%) or 0.001ppm—10^(6)ppm |
| Resolution | 0.1μg water |
| Display | LCD color 7-inch large screen display |
| Accuracy | When the water content is 3-1000μg water, the error of the measured value is ≤±2μg; When the water content is above 1000μg water, the error of the measured value is ≤±0.2% (excluding the error of sampling) |
| End Point Indication | Screen display/sound warning/printout/end point light prompt |
| Blank Processing | The blank current microprocessor automatically controls the compensation to ensure that the blank can be accurately deducted within the sample enrichment time of 10 minutes. |
| Stirring Speed | Adjustable control |
| Drift Compensation | Automatic microprocessor control |
| Data Input | Touch screen operation |
| Sample No. | User defined |
| Electrolysis Speed | Peak value: 2.4 mg water/min |
| Electrolytic Current | 0-430mA |
| Storage | Can store historical data |
| Printing | Built-in thermal high-efficiency printer, 56mm paper width |
| Print Content | μg/ppm/percent content/formula/date and time |
| Display State | Real-time drawing of colored titration curves |
| Self-check Function | Automatic diagnosis of instrument faults |
| Calendar/Clock | Analysis time, date display and printout (not lost when power off) |
| Power Consumption | <100W |
| Electricity | 220V±10%,50Hz±2.5Hz |
| Use Environment | Temperature 5—40℃, humidity<85% |
| Optional Function | Automatic liquid filling and draining function |
| Dimension | 350*260*198mm |
| N.W./G.W. | 10kg/13kg |
| Shipping Dimension | 450*450*300mm |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Volumetric Titration / Range: (0.1mg~250.0)mg; Volumetric Titration / Polarization Current: (1±0.2)μA, (50±10)μA. Match sample matrix, measurement method, concentration range and reagent needs.
Measurement Range: 3%~35%; Ambient Temperature Range: 0~40℃. Match sample matrix, measurement method, concentration range and reagent needs.
Volumetric Titration / Range: 0.1mg~250mg; Volumetric Titration / Polarization Current Accuracy: 0.1mg. Match sample matrix, measurement method, concentration range and reagent needs.