Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Microwave Digestion System, MDS-Tan40 is listed in VVON's sample digestion & laboratory reactors range for Bangladesh. Published models: MDS-Tan40. Match sample chemistry, vessels, working volume and operating conditions. For a quotation, send the sample chemistry, vessel type, volume, temperature and pressure requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | MDS-Tan40 |
|---|---|
| Working environment temperature | 0~40℃ |
| Relative humidity for working environment | 15~80%RH |
| Microwave source | 2450MHz; Max. microwave output power 2000W, emitted from Dual magnetron inverter high-energy microwave field; non-pulse continuous microwave output |
| Installed power | 3800W |
| Microwave cavity | Grade 316L stainless steel microwave resonant cavity, with a wall thickness of more than 3mm, sprayed with multi-layer PFA coating. |
| Furnace exhaust system | Automatically adjusted air volume; cooling to room temperature in less than 15 minutes |
| Dimensions(W*D*H) | 600×685×660 |
| Net weight | 62kg |
| Vessel type | High-Pressure | Auto-release | High-Pressure | Ultra High-Pressure |
|---|---|---|---|---|
| Batch amount | 40 vessels | 40 vessels | 24 vessels | 18 vessels |
| Inner vessel material | TFM | TFM | TFM | TFM |
| Outer vessel material | Aerospace composite fiber | Aerospace composite fiber | Aerospace composite fiber | Aerospace composite fiber |
| Inner vessel volume | 70mL | 55mL | 110mL | 100mL |
| Max. temperature | 300℃ | 300℃ | 300℃ | 320℃ |
| Max. pressure | 15Mpa | 15Mpa | 15Mpa | 15Mpa |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Vessel Volume: 100ml; Temperature Measurement Range: RT. ~ 400℃, accuracy: 0.1℃. Match sample chemistry, vessels, working volume and operating conditions.
Sample Digestion & Laboratory Reactors by BIOBASE. Match sample chemistry, vessels, working volume and operating conditions.
Vessel Volume: 50mL. Match sample chemistry, vessels, working volume and operating conditions.