Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Microvolume UV/Vis (Nano) Spectrophotometer, SP-YUV100 is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: SP-YUV100. Published details include Sample volume: 0.5μL~2μL. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | SP-YUV100 |
|---|---|
| Sample volume | 0.5μL~2μL |
| Path Length | 0.05mm, 0.2mm , 1mm |
| Light source/Life | Xenon Lamp/flicker times>10^9 |
| Detector type | 2048 CMOS array |
| Wavelength | 180~910nm |
| Wavelength accuracy | ±1 nm |
| Wavelength precision | ±0.2nm |
| Spectral resolution | ≤1.5nm(FWHM@Hg 253.7nm) |
| Absorbance precision | 0.002Abs |
| Absorbance accuracy | ±1%(7.332Abs at 260nm) |
| Absorbance range(equaled 10mm) | 0.04~300A; Cuvette (OD600 ):0~4A |
| Nucleic acid range | dsDNA:2~15000ng/μL ssDNA:1.32~9900ng/μL RNA:1.6~12000ng/μL |
| Protein Detection Range | A280: 0.04~750mg/mL BSA: 0.06~1119mg/mL IgG: 0.03~547mg/mL Lysozyme: 0.015~284mg/mL |
| Detection time | <6S |
| OD600 / Abs range | 0~4.000 Abs |
| OD600 / Abs stability | [0,3)≤0.5%, [3,4)≤1.5% |
| OD600 / Abs repeatability | [0,3)≤0.5%, [3,4)≤1.5% |
| OD600 / Abs accuracy | [0,2)≤0.005A,[2,3)≤1%,[3,4)≤2% |
| Sample pedestal | 304 stainless steel and Quartz fiber |
| Voltage | DC12V 4A |
| Power of work/Stand by | 48W/ <6.5W |
| Dimension | 270×210×196 mm(W×D×H) |
| Weight | 3.4 kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Measurement range: 0~100. Compare measurement range, optical configuration, sample format and software.
Wavelength Range(nm): 700nm~2500nm. Compare measurement range, optical configuration, sample format and software.
Wavelength Range: 400-700nm. Compare measurement range, optical configuration, sample format and software.