Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Laser Particle Size Analyzer, Professional PSA-2L2309A is listed in VVON's particle size rheology & physical analysis range for Bangladesh. Published models: PSA-2L2309A. Match the material, property, measurement range and sample-preparation method. For a quotation, send the material, property to measure, measurement range and sample preparation. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Item | Function |
|---|---|
| Analysis Modes | Free Distribution, R-R Distribution, Log-Normal Distribution, Mesh Size Classification, etc., meet the diverse particle size statistical requirements of different industries. |
| Statistical Methods | Volume Distribution, Quantity Distribution |
| Statistical Comparison | It can conduct comparative analysis on multiple test results. By comparing test results of different batches of samples, samples before and after processing, and samples tested at different times, differences can be identified. This is of great practical significance for quality control of industrial raw materials. |
| User-defined Analysiss | Calculate the percentage based on particle size. Calculate the particle size based on the percentage. Calculate the percentage based on the particle size range. These functions meet the representativeness requirements of particle testing across various industries. |
| Model | PSA-2L2309A |
|---|---|
| Instrument type | Wet and Dry |
| Specification | Specification |
| Measuring range | Wet: 0.01μm to 3500μm; Dry: 0.1μm to 3000μm |
| Photodetector | Wet: 116; Dry: 116 |
| Accuracy | Wet: ≤0.5% (CRM D50); Dry: ≤1% (CRM D50) |
| Repeatability | Wet: ≤0.5% (CRM D50); Dry: ≤1% (CRM D50) |
| Design principle | Laser Diffraction |
| Analysis principle | Mie Scattering; Fraunhofer Diffraction |
| Standard | ISO 13320 |
| Audit trail | Optional FDA software |
| Engineering | Engineering |
| Laser | Fiber Laser, 639nm, Max. 4mW |
| Laser safety | Class 1 |
| Detector | Log-spaced array, 0.015° to 145° |
| Operation mode | Full Automatic; Manual Control |
| Optical alignment | Full Automatic |
| Test speed | Wet: ≤2min; Dry: ≤1min; Typical testing time: ≤10s; Inverval time per test result: 500ms |
| Wet dispersion | Wet dispersion |
| Ultrasonic | Frequency: 40kHz; Power: 60W; Time: adjustable |
| Stirrer | Speed: 0rpm to 3000rpm adjustable |
| Circulate | Rated Flow: 1-8L/min; Rated Power: 120W |
| Sample tank | Volume: 600mL |
| Micro-sample cuvette | Optional |
| Dry dispersion | Dry dispersion |
| Dry dispersion | Dry-turbulence dispersion patent, normal shock wave shear technique |
| Sample feeding | Automatic Sampler (SOP setting) |
| Dispersion medium | Compressed Air |
| Technical data | Technical data |
| Connect PC, LIMS | Yes |
| Test Report | Word, Excel, Image, Text, etc. |
| Working environment | Temperature: 5℃ to 35℃; Humidity: <85% |
| Storage environment | Temperature: -20℃ to 50℃ |
| Power supply | 220V, 50/60Hz |
| Product dimensions (L×W×H) | 870mm×370mm×330mm; 420mm×350mm×380mm 260mm×290mm×140mm |
| Net weight | 32kg; 15kg 7kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by Infitek. Match the material, property, measurement range and sample-preparation method.