Infitek Dry Bath / Block Heater, DBI-160/130 Series is listed in VVON's water baths chillers & dry blocks range for Bangladesh. Published models: DBI-160-1, DBI-160-2, DBI-130-4. Match temperature range, stability, sample format and circulation requirements. For a quotation, send the temperature range, working volume, sample format and connected equipment. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Product model | Parameters | Parameters | Parameters |
|---|---|---|---|
| Product model | DBI-160-1 | DBI-160-2 | DBI-130-4 |
| Temperature range | RT.+5°C~160°C | RT.+5°C~160°C | RT.+5°C~130°C |
| Temp accuracy | ±0.5℃(@40℃) | ±0.5℃(@40℃) | ±0.5℃(@40℃) |
| Temp accuracy | ±1℃(@120℃) | ±1℃(@120℃) | ±1℃(@120℃) |
| Temp uniformity | ±0.5℃ | ±0.5℃ | ±0.5℃ |
| Display accuracy | 0.1℃ | 0.1℃ | 0.1℃ |
| Time range | 1-99h59min/∞ | 1-99h59min/∞ | 1-99h59min/∞ |
| Heating time | ≤15min(from 25℃ to 160℃) | ≤15min(from 25℃ to 160℃) | ≤20min(from25℃ to 130℃) |
| Block quantity | 1 | 2 | 4 |
| Max power | 300W | 500W | 600W |
| Voltage | AC220V or AC110V, 50/60Hz | AC220V or AC110V, 50/60Hz | AC220V or AC110V, 50/60Hz |
| Size | 260 x 220 x 100mm | 260 x 220 x 100mm | 360 x 220 x 100mm |
| Weight | 5.0kg | 5.5Kg | 8.0kg/9.2kg |
| Package Dimension (W*D*H)(mm) | 370*370*260 | / | 430*330*220 |
| Type | Diameter of test tube | Number of test tube | |
|---|---|---|---|
| MD01 | 6mm | 48 | Hole depth 47mm |
| MD02 | 7mm | 48 | Hole depth 47mm |
| MD03 | 10mm | 24 | Hole depth 47mm |
| MD04 | 12mm | 24 | Hole depth 47mm |
| MD05 | 13mm | 24 | Hole depth 47mm |
| MD06 | 15mm | 16 | Hole depth 47mm |
| MD07 | 16mm | 16 | Hole depth 47mm |
| MD08 | 19mm | 12 | Hole depth 47mm |
| MD09 | 20mm | 12 | Hole depth 47mm |
| MD10 | 26mm | 8 | Hole depth 47mm |
| MD11 | 28mm | 4 | Hole depth 47mm |
| MD12 | 40mm | 3 | Hole depth 47mm |
| MD13 | 0.2ml centrifuge tube | 48 | Standard centrifuge tube |
| MD14 | 0.5ml centrifuge tube | 48 | Standard centrifuge tube |
| MD15 | 1.5ml centrifuge tube | 24 | Standard centrifuge tube |
| MD16 | 2.0ml centrifuge tube | 24 | Standard centrifuge tube |
| MD17 | 0.2ml PCR plate | 96 | Not applicable to DBI-160-1 |
| MD18 | 0.2ml Elisa plate | 96 | Not applicable to DBI-160-1 |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temp. range: RT.+5℃~99℃. Match temperature range, stability, sample format and circulation requirements.
Water Baths Chillers & Dry Blocks by Infitek. Match temperature range, stability, sample format and circulation requirements.
Function / Temp. Range: RT+5~100℃; Specification / Volume: 3.4L. Match temperature range, stability, sample format and circulation requirements.