Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Dry Bath / Block Heater, DBI-100VII is listed in VVON's water baths chillers & dry blocks range for Bangladesh. Published models: DBI-100VII, MiniBoxA, MiniBoxB, MiniBoxC, MiniBoxD, MD40. Published details include Temp setting range: 0°C ~100°C; Temp control range: RT+5°C ~100°C. Match temperature range, stability, sample format and circulation requirements. For a quotation, send the temperature range, working volume, sample format and connected equipment. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | DBI-100VII |
|---|---|
| Temp setting range | 0°C ~100°C |
| Temp control range | RT+5°C ~100°C |
| Timing range | 1min ~ 99h59min/∞ |
| Temp accuracy | ≤±0.3°C*@37°C |
| Display accuracy | 0.1°C |
| Temp uniformity | ≤±0.3°C@37°C * |
| Heating time | ≤15min(from 25°C~100°C) |
| Auto heating | Yes |
| Auto running | Yes |
| Auto resume to run | Yes |
| Temperature control group | 2 |
| Block quantity | 4 |
| Power | 240W |
| Electricity | AC110V or AC220V/50-60Hz |
| Fuse | 250V 3A Ф5×20 |
| Dimension | 370*254*217(mm) |
| Package Dimension (W*D*H) (mm) | 460*370*320 |
| N.W. / G.W. | 5.0kg / 6.3kg |
| Model | Capacity | Model | Capacity |
|---|---|---|---|
| MiniBoxA | 15*2.0ml centrifuge tube | MD40 | 15*Φ10mm |
| MiniBoxB | 15*1.5ml centrifuge tube | MD41 | 12*Φ12mm |
| MiniBoxC | 24*0.5ml centrifuge tube | MD42 | 8*Φ15mm |
| MiniBoxD | 32*0.2ml centrifuge tube | MD43 | 8*Φ16mm |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temp. setting range: 0°C ~110°C; Temp. control range: RT+5°C ~110°C. Match temperature range, stability, sample format and circulation requirements.
Temp setting range: 0℃~100℃; Temp control range: RT.-20℃~100℃. Match temperature range, stability, sample format and circulation requirements.
Water Baths Chillers & Dry Blocks by Infitek. Match temperature range, stability, sample format and circulation requirements.