Brand: Infitek | Category: Medical Equipment
Infitek Automated Tissue Processor, TSP-3 is listed in VVON's histology & pathology equipment range for Bangladesh. Published details include Dehydration basket capacity: 150*48*82 (mm) (60 dehydration cassettes); Capacity of Single Cup: 1000ml. Match specimen throughput, preparation steps and consumables to the histology workflow. For a quotation, send the specimen workload, preparation method, accessories and consumables. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Number of Cups | 12 (nine cups for reagents and three cups for paraffin) |
|---|---|
| Dehydration basket capacity | 150*48*82 (mm) (60 dehydration cassettes) |
| Capacity of Single Cup | 1000ml |
| Single tank processing time | Single tank processing time |
| First tank | Adjustable from 0~99 hours 59 minutes |
| Other tanks | Adjustable from 0~23 hours 59 minutes |
| Wax tank temperature control range | RT ~80°C adjustable |
| Programmable settings | 20 sets. |
| Temperature Control Precision | ±1℃ |
| Drainage time | Adjustable from 10~60 seconds, increment of 10 seconds; shake/drip above cup |
| Stirring frequency | Adjustable from 0-6 times/minute |
| Tissue protection tanks | Adjustable from 1~7 tanks |
| Acceptable Temperature Range of Operation Environment | 0 ~ 40℃ |
| Working Voltage | AC 220V±10% 50Hz (standard model); AC110V±10% 60Hz |
| Power | 500W |
| Dimensions | 1010×420×450 mm (W×D×H) |
| Net weight | 67 kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Temp. control range: RT+5 ℃ ~100 ℃; Temp. setting range: 0℃~100℃. Match specimen throughput, preparation steps and consumables to the histology workflow.
Capacity of Each Cup: 1500ml; Dehydration basket capacity: 160*52*112 (mm) (100 dehydration cassettes). Match specimen throughput, preparation steps and consumables to the histology workflow.
Capacity of Each Cup: 1500ml; Capacity of Staining Rack: 70pcs.. Match specimen throughput, preparation steps and consumables to the histology workflow.