Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Atomic Absorption Spectrophotometer, SP-IAA4530 is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: SP-IAA4530. Published details include Wavelength range: 190-900nm. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | SP-IAA4530 |
|---|---|
| Atomization System | Flame Atomization System |
| Wavelength range | 190-900nm |
| Spectral bandwidth | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength Accuracy | ±0.15nm |
| Wavelength Repeatability | ≤0.04nm |
| Baseline stability | ≤0.002A/30min (Cu) |
| Characteristic Concentration | 0.02μg/ml/1% (Cu) |
| Detection limit | 0.004μg/ml (Cu) |
| Preciseness | 0.50% |
| Grating | 1800 lines/mm |
| Inflamer | All-metal titanium burner |
| Atomizer | Effective glass atomizer |
| Lamp stand | 8 |
| D2 background correction ability | When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method |
| Power supply | 220V±22V AC |
| Package size(mm) | 840×700×780(Main instrument) |
| Package size(mm) | 1170×645×900(Accessories) |
| Acetylene air burner | 100mm |
|---|---|
| Ignition dynamic baseline drift | ≤0.006A/30min |
| (Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
| Related standard deviation of the accuracy | ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
| Safety system | Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner |
| The highest temperature | 3000℃ |
|---|---|
| The largest temperature rising speed | ≥2000℃/s |
| Characteristic quantity | Cd≤0.5×10^(-12)g Cu≤0.5×10^(-11)g |
| Accuracy | Cu≤3% Cd≤3% |
| Size and weight | 730mm×625mm×700mm 79.3kg |
| Safety system | Over current protection; Low air pressure alarm/protection; Low cooling water flow alarm/protection |
| Power source and power | 220V±22V AC 7000W |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Spectrometers & Optical Analysis by Infitek. Compare measurement range, optical configuration, sample format and software.
Wavelength Range: 400-700nm. Compare measurement range, optical configuration, sample format and software.
Wavelength Range: 190-1100nm. Compare measurement range, optical configuration, sample format and software.