Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Polarimeter BK-P Series is listed in VVON's particle size rheology & physical analysis range for Bangladesh. Published models: BK-P810, BK-P810A, BK-P810Pro, BK-P850, BK-P850A, BK-P850Pro. Match the material, property, measurement range and sample-preparation method. For a quotation, send the material, property to measure, measurement range and sample preparation. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-P810 | BK-P810A | BK-P810Pro | BK-P810Pro | BK-P850 | BK-P850A | BK-P850Pro |
|---|---|---|---|---|---|---|---|
| Light Source | LED lamp | LED lamp | LED lamp | LED lamp | LED lamp | LED lamp | LED lamp |
| Measuring Range | ±89.99°, 259°Z | ±89.99°, 259°Z | ±89.99°, 259°Z | ±89.99°, 259°Z | ±89.99°, 259°Z | ±89.99°, 259°Z | ±89.99°, 259°Z |
| Wavelength | 589.3nm | 589.3nm | 589.3nm | 589.3nm | 589.3nm | 589.3nm | 589.3nm |
| Readable Accuary | 0.001° | 0.001° | 0.001° | 0.001° | 0.001° | 0.001° | 0.001° |
| Measuring Accuracy | 0.02° | 0.02° | 0.02° | 0.02° | 0.02° | 0.02° | 0.02° |
| Repeatability | 0.002° | 0.002° | 0.002° | 0.002° | 0.002° | 0.002° | 0.002° |
| Sample Transmittance | >0.1% | >0.1% | >0.1% | >0.1% | >0.1% | >0.1% | >0.1% |
| Temp. Control Range | \ | \ | \ | Built in Peltier, 15 -30eC, +0.3°C | Built in Peltier, 15 -30eC, +0.3°C | Built in Peltier, 15 -30eC, +0.3°C | Built in Peltier, 15 -30eC, +0.3°C |
| Test Mode | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z | Optical rotation, optical specific rotation, concentration, sugar scale Z |
| Display | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) | 5.6” color touch screen; ( 8” color touch screen for BK-P810Pro/850Pro) |
| Data Storage Capacity | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) | 1000sets; (8GB for BK-P810Pro/850Pro) |
| Interface | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) | RS232 or USB; Excel format and “Blue Ocean” format; (WI-FI for BK-P810Pro/850Pro) |
| Atlas Duration | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro | 4 Hours only for BK-P810Pro/P850Pro |
| Power Consumption | 250W | 250W | 250W | 250W | 250W | 250W | 250W |
| Power Supply | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz | AC220V±10%, 50Hz |
| External Size(W*D*H) | 708*330*287mm | 708*330*287mm | 708*330*287mm | 708*330*287mm | 708*330*287mm | 708*330*287mm | 708*330*287mm |
| Package Size(W*D*H) | 840*455*445mm | 840*455*445mm | 840*455*445mm | 840*455*445mm | 840*455*445mm | 840*455*445mm | 840*455*445mm |
| Gross Weight | 30kg I 40kg | 30kg I 40kg | 30kg I 40kg | 30kg I 40kg | 30kg I 40kg | 30kg I 40kg | 30kg I 40kg |
| ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. | ・"AM" in BK-P810A and BK-P850A mean automatic calibrate optical rotation. |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Particle Size Rheology & Physical Analysis by BIOBASE. Match the material, property, measurement range and sample-preparation method.
Micro tube: Sample capacity less than 0.8 mL; length 50 mm; for BK-P2S, BK-P2B, BK-P1, BK-P2, BK-P3 and BK-P4; Thermostatic tube: For BK-P2; approximately 100 mm length; 2.5 mL sample volume. Match the material, property, measurement range and sample-preparation method.
Particle Size Rheology & Physical Analysis by BIOBASE. Match the material, property, measurement range and sample-preparation method.