Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE High and Low Temperature Test Chamber is listed in VVON's laboratory incubators & growth chambers range for Bangladesh. Published models: BJPX-HL50C/D, BJPX-HL80C/D/E, BJPX-HL100C/D/E, BJPX-HL150C/D/E, BJPX-HL225C/D/E, BJPX-HL408C/D/E. Compare the remaining models in the specification tables. Compare chamber capacity and required temperature, atmosphere, humidity or agitation. For a quotation, send the application, working volume, temperature and atmosphere requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BJPX-HL50C/D | BJPX-HL80C/D/E | BJPX-HL100C/D/E | BJPX-HL150C/D/E | BJPX-HL225C/D/E | BJPX-HL225C/D/E | BJPX-HL408C/D/E | BJPX-HL800C/D/E | BJPX-HL1000C/D/E |
|---|---|---|---|---|---|---|---|---|---|
| Capacity | 50L | 80L | 100L | 150L | 225L | 225L | 408L | 800L | 1000L |
| Temperature Range | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ | Low temperature: C: -20℃; D: -40℃; E: -60℃ High temperature: 150℃ |
| Humidity Range | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH | 20~98% RH |
| T&H Analytical Accuracy | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH | ±0.1℃, ±1%RH |
| T&H Uniformity | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH | ±1℃, ±2%RH |
| T&H Control Accuracy | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH | ±0.5℃, ±1%RH |
| T&H Fluctuation | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH | ±2℃, ±3%RH |
| Heating/Cooling Rate | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) | Heating: 1~3°C/min (avg.); cooling: 0.7~1°C/min (avg.) |
| Inner & Outer Material | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 |
| Insulation Material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material | High temperature resistant high-density ethyl chloroformate foam insulation material |
| Cooling System | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ | Air cooling, single compressor: -20~-40℃ Air cooling, water cooling, double compressors: -60~-70℃ |
| Safety Protection | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system | No-fuse switch, compressor overload protection switch, refrigerant high/low pressure protection switch, over-humidity and over-temperature protection switch, fuse, fault alarm system |
| Power Supply | AC 220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer) Wiring method: air switch | AC 220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer) Wiring method: air switch | AC 220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer) Wiring method: air switch | AC 220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer) Wiring method: air switch | AC 220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer) Wiring method: air switch | AC 380V, 50/60Hz Wiring method: air switch | AC 380V, 50/60Hz Wiring method: air switch | AC 380V, 50/60Hz Wiring method: air switch | AC 380V, 50/60Hz Wiring method: air switch |
| Standard Accessory | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface | Observation window, 50mm test hole, PL box light, partition, wet and dry ball gauze, RS232, USB interface |
| Optional Accessory | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door | Operating hole with built-in glass door |
| Internal Size(W*D*H)mm | 350*350*400 | 400*400*500 | 500*400*500 | 500*500*600 | 600*500*750 | 600*500*750 | 800*600*850 | 1000*800*1000 | 1000*1000*1000 |
| External Size(W*D*H)mm | 580*980*1350 | 950*1050*1400 | 1050*1050*1400 | 1050*1150*1500 | 1150*1150*1650 | 1150*1150*1650 | 1350*1250*1750 | 1520*1550*1900 | 1550*1650*1900 |
| Package Size(W*D*H)mm | 700*1200*1500 | 1150*1250*1700 | 1250*1250*1700 | 1250*1350*1800 | 1350*1350*1950 | 1350*1350*1950 | 1550*1450*2050 | 1750*1650*2200 | 1750*1850*2200 |
| Net Weight | 180kg | 240kg | 250kg | 260kg | 290kg | 290kg | 330kg | 380kg | 410kg |
| Gross Weight | 200kg | 270kg | 280kg | 290kg | 325kg | 325kg | 365kg | 415kg | 435kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Laboratory Incubators & Growth Chambers by BIOBASE. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Capacity: 24-well blood typing regent card(Compatible with 6-column and 8-column formats); Temp. Range: RT+5~60℃. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Capacity: 610L; Temperature Control Range: 4~60℃. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.