BIOBASE Auto Blot System (Western Blot System)

Brand: BIOBASE | Category: Medical Equipment

BIOBASE Auto Blot System (Western Blot System) is listed in VVON's histology & pathology equipment range for Bangladesh. Published models: XD236. Published details include Test Strip Capacity: 1-36 or 1-30 strip; Programming Capacity: ≥ 38+2 (fixed procedure). Match specimen throughput, preparation steps and consumables to the histology workflow. For a quotation, send the specimen workload, preparation method, accessories and consumables. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelXD236
Test Strip Capacity1-36 or 1-30 strip
Programming Capacity≥ 38+2 (fixed procedure)
Number of Programmable Steps20 steps* 6 working phases
Liquid Dispensation SystemStandard 6-channel pumps liquid dispensing system
Pump Dispensing Range / Increment250μl ~ 3000μl, 1μl increment
Accuracy of The Pump Dispensing±3.0% (dispensing volume 2000μl )
Precision of The Pump DispensingCV ≤ 5.0% (dispensing volume 2000μl)
Quantitative CorrectionQuantitative correction
Incubation Time / Increment0~24 hours / 1 min increment; can be recycled
Incubation Time DisplayHours, minutes and seconds
Shaking Speed3 gear optional
Temperature Control of ShakerAccuracy ± 1.5 ℃, Fluctuation ≤ 0.2 ℃ at 37 ℃; Accuracy ± 1.5 ℃, Fluctuation ≤ 0.25 ℃ at 30 ℃ or 25 ℃
DisplayDot matrix LCD with backlight
CommunicationRS232 Interface, Baud 9600, Data bit 8, stop bit 1, parity check: NO
AlarmingAlarms for reagents dispensing, waste overflow, work ending etc.
CleaningAutomatic rinsing when necessary
Reagent Bottle Capacity200ml *5
Wash Bottle Capacity1000 ml* 1
Waste Bottle Capacity2000ml*1 (airtight negative-pressure liquid waste bottle)
Cross ContaminationWhen negative and positive samples are tested in turn, the negative samples should not show positive bands
Working ConditionIndoor use, altitude ≤ 3000m, 5~40 ℃, RH ≤ 80% at temperature < 31 ℃
Power Supply110~240V, 50/60Hz, 250VA
External Size(W*D*H)630*500*400mm
Packed Size(W*D*H)840*630*840mm
Net weight33kg
Gross weight70kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment

View full category