Brand: GEMMY Industrial | Category: Medical Equipment
A Class B table top steriliser with a 40 litre chamber measuring 300 mm diameter by 570 mm deep, running at 121 or 135 degrees C with an automatic fill water system and a vacuum assisted drying stage selectable at 0, 15, 30, 35 or 40 minutes. Programmes cover wrapped and unwrapped loads, dry and undried, liquids, a PRION programme, Bowie-Dick and a pump test, with temperature shown digitally, pressure on a pressure and vacuum gauge and programme status on LED. It draws 3000 W at 14 A, split between a 2300 W heater, a 600 W dry heater and a 100 W vacuum pump, from a 230 V 50/60 Hz supply. Safety cover includes a 2.5 kg/cm2 pressure safety valve, independent over temperature protection, two 30 A no fuse breakers, an over pressure switch, a door lock micro-switch, water level sensors in both the tank and the chamber, and a silicone bellows pressure door lock.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about GEMMY Industrial equipment requirements in Bangladesh.
Phone: +880 1711-738207 | Email: info@vvon.com.bd
A vertical steam steriliser whose cycle runs automatically through conditioning and sterilising phases, with sterilising temperature adjustable from 121 to 132 degrees C and sterilising time from 0 to 60 minutes. The timer only starts once the preset temperature has been reached, and a buzzer announces completion and cuts the heating supply. The cylindrical chamber is SUS 316 stainless steel with a polished surface, thermally insulated with fibreglass and clad in stainless sheet, fitted with a steam trap to discharge condensate and a HEPA air filter to keep contaminated air out. The door is operated manually by a rotating handle with a foot pedal to lift it, sealed by a silicone rubber gasket, and safety cover includes a door interlock, a safety valve, over temperature cut-off, circuit breaker and fuse protection, and a manual emergency exhaust for power outages.
A bench top steam steriliser with a 230 mm diameter by 390 mm deep chamber in 304 stainless steel, approximately 16 litres, in an overall cabinet of 501 x 406 x 537 mm. Design temperature is 140 degrees C and the published working range for unwrapped, wrapped and liquid loads is 115 to 134 degrees C at 0.9 to 2.1 kg/cm2. GEMMY states the autoclave is manufactured in conformity with directive 93/42/EEC. Safety fittings are a safety valve, an emergency exhaust valve, a release valve, a door safety holder and a pressure control switch.
A 72 litre vertical steam steriliser with a 350 x 750 mm chamber, working from 120 to 134 degrees C under pressure control, with a gross weight of 140 kg. A semi-automatic control system uses a sterilising and drying switch to select which function runs, and both sterilising and drying times are adjustable from 0 to 60 minutes on the timer. The timer starts only after the preset temperature is reached, illuminated pilot lamps show status, and a buzzer announces completion and cuts the heating supply. An automatic air venting device discharges cool air from the chamber to obtain effective saturated steam, and the machine comes with a sterilisation basket, two tube indicators, a shelf and a hose.