Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Rotary Evaporator, lab-scale, REV-2000AX, REV-3000AX, REV-5000AX is listed in VVON's evaporators concentrators & freeze dryers range for Bangladesh. Published models: REV-2000AX, REV-3000AX, REV-5000AX. Match sample volume, solvent, temperature and vacuum requirements. For a quotation, send the sample or solvent, batch size, temperature limits and vacuum accessories. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | REV-2000AX | REV-3000AX | REV-3000AX | REV-5000AX | REV-5000AX |
|---|---|---|---|---|---|
| Rotating Speed | Color LCD Screen; 0~310rpm | Color LCD Screen; 0~310rpm | Color LCD Screen; 0~310rpm | Color LCD Screen; 0-310rpm (Evaporating flask≤ 3L) 0-200rpm (Evaporating flask≤ 5L) | Color LCD Screen; 0-310rpm (Evaporating flask≤ 3L) 0-200rpm (Evaporating flask≤ 5L) |
| Evap. Capacity | Max.25ml/min (H2O) | Max.27ml/min (H2O) | Max.27ml/min (H2O) | Max.43ml/min (H2O) | Max.43ml/min (H2O) |
| Temp. range/precision | Microcomputer PID controller; Water Bath:RT.-99℃±0.5℃;Oil Bath:RT.-210℃±2℃ | Microcomputer PID controller; Water Bath:RT.-99℃±0.5℃;Oil Bath:RT.-210℃±2℃ | Microcomputer PID controller; Water Bath:RT.-99℃±0.5℃;Oil Bath:RT.-210℃±2℃ | Microcomputer PID controller; Water Bath:RT.-99℃±0.5℃;Oil Bath:RT.-210℃±2℃ | Microcomputer PID controller; Water Bath:RT.-99℃±0.5℃;Oil Bath:RT.-210℃±2℃ |
| Bath Material | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. |
| Bath Size | φ23*13cm(about 5.4L) | φ26*15cm(about 8L) | φ26*15cm(about 8L) | φ29*17cm(about 11L) | φ29*17cm(about 11L) |
| Positive&Negative Rotating | Intermittent positive and negative rotating function with timing function (0-60s) for drying process. | Intermittent positive and negative rotating function with timing function (0-60s) for drying process. | Intermittent positive and negative rotating function with timing function (0-60s) for drying process. | Intermittent positive and negative rotating function with timing function (0-60s) for drying process. | Intermittent positive and negative rotating function with timing function (0-60s) for drying process. |
| Lift | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. |
| Temp. Set | Rotating switch coding for temperature setting with big LCD screen display. | Rotating switch coding for temperature setting with big LCD screen display. | Rotating switch coding for temperature setting with big LCD screen display. | Rotating switch coding for temperature setting with big LCD screen display. | Rotating switch coding for temperature setting with big LCD screen display. |
| Safety | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. |
| Heater Power | 1.5kW | 1.5kW | 1.5kW | 1.5kW | 1.5kW |
| Evaporating flask Volume | 0.25–2L | 0.25–3L | 0.25–3L | 0.25–5L | 0.25–5L |
| Sealing | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. |
| Condenser | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. |
| Condense Area | 0.18㎡ | 0.21㎡ | 0.21㎡ | 0.31㎡ | 0.31㎡ |
| Environment Temp. | 5℃~40℃ | 5℃~40℃ | 5℃~40℃ | 5℃~40℃ | 5℃~40℃ |
| IP(Ingress Protection) | IP42 | IP42 | IP42 | IP42 | IP42 |
| Factory Configuration | 29# grinding mouth integrated rotating shaft *1; Sample Bottle: 29# Eggplant bottle 1L*1; Recycling Bottle: S35 ball grinding mouth collection bottle 1L*1 | Flange interface to 29# grinding interface*1; Sample Bottle: 3L flange mouth round bottom bottle *1, 29# eggplant bottle 1L*1; Recycling Bottle:S35 ball grinding mouth collection bottle 2L*1 | Flange interface to 29# grinding interface*1; Sample Bottle: 3L flange mouth round bottom bottle *1, 29# eggplant bottle 1L*1; Recycling Bottle:S35 ball grinding mouth collection bottle 2L*1 | Flange interface to 29# grinding mouth interface *1; Sample Bottle: F50 flange mouth round bottom bottle 5L*1, 29# eggplant bottle 1L*1; Recycling Bottle: S35 ball grinding mouth collection bottle 3L*1 | Flange interface to 29# grinding mouth interface *1; Sample Bottle: F50 flange mouth round bottom bottle 5L*1, 29# eggplant bottle 1L*1; Recycling Bottle: S35 ball grinding mouth collection bottle 3L*1 |
| Electricity | AC220V/50Hz | AC220V/50Hz | AC220V/50Hz | AC220V/50Hz | AC220V/50Hz |
| Instrument Dimension(W*D*H)(mm) | 660*420*830 | 660*420*830 | 700*430*860 | 700*430*860 | 740*440*960 |
| Package Dimension(W*D*H)(mm) | 740*670*530 | 740*670*530 | 710*645*790 | 710*645*790 | 810*710*890 |
| G.W.(kg) | 30 | 30 | 35 | 35 | 49 |
| Supporting products | REV-2000AX; +Diaphragm Vacuum Pump VACP-D20; +Low Temperature Circulator RECL20-2X | REV-2000AX; +Diaphragm Vacuum Pump VACP-D20; +Low Temperature Circulator RECL20-2X | REV-3000AX; +Diaphragm Vacuum Pump VACP-D20; +Low Temperature Circulator RECL20-2X | REV-3000AX; +Diaphragm Vacuum Pump VACP-D20; +Low Temperature Circulator RECL20-2X | REV-5000AX; +Diaphragm Vacuum Pump VACP-D45L; +Low Temperature Circulator RECL20-5X |
| Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. | Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. | Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. | Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. | Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. | Optional:Vacuum controller for precise vacuum control. Warning: The protection cap is only for water bath experiment. Please do not use in oil bath experiment. |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Evaporation Capacity: Max.25mL/min(H_(2)O). Match sample volume, solvent, temperature and vacuum requirements.
Evaporators Concentrators & Freeze Dryers by Infitek. Match sample volume, solvent, temperature and vacuum requirements.
Temp range: RT.+5°C -160°C. Match sample volume, solvent, temperature and vacuum requirements.