Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Portable Multi-parameter Analyzer, BEP-269 is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: BEP-269. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BEP-269 |
|---|---|
| Instrument Specifications | Instrument Specifications |
| Display Screen | 3.3-inch monochrome LCD display |
| Dimensions | 200mm × 101mm × 36mm |
| Weight | 420g |
| External Interfaces | Electrode interface *2, USB *1 |
| Data Storage | Automatic interval saving, automatic lock saving |
| Language | Chinese / English |
| GPS | Supports query and automatic saving |
| Protection Level | IP67 |
| Power Supply | Lithium battery / AA NiMH battery |
| Relative Humidity | 10 ~ 85% RH (non-condensing) |
| Operating Ambient Temperature | -5 ~ 50℃ |
| Transportation and Storage Conditions | Temperature: -15 ~ 65℃, Relative humidity: 5 ~ 85% RH (non-condensing) |
| Sensor Specifications | Sensor Specifications | Sensor Specifications |
|---|---|---|
| pH | Measurement Principle | Glass electrode method |
| pH | Measurement Parameters | pH, Temperature |
| pH | Range | pH: 0 ~ 14, Temperature: 0 ~ 60℃ |
| pH | Accuracy | ≤ ±0.02 pH |
| pH | Repeatability | ≤ ±0.02 pH |
| pH | Resolution | 0.01 pH |
| pH | T90 Response Time | ≤ 20s |
| pH | Material | Glass, PC |
| pH | Dimensions | Φ27 × 167mm |
| pH | Cable Length | Default 1.5m (customizable) |
| pH | Waterproof Rating | IP68 |
| Dissolved Oxygen | Measurement Principle | Fluorescence quenching method |
| Dissolved Oxygen | Measurement Parameters | Dissolved oxygen (concentration and saturation), Temperature |
| Dissolved Oxygen | Range | Dissolved oxygen: 0 ~ 20 mg/L, Saturation: 0 ~ 200%, Temperature: 0 ~ 50℃ |
| Dissolved Oxygen | Accuracy | ≤ ±0.3 mg/L |
| Dissolved Oxygen | Repeatability | ≤ ±0.3 mg/L |
| Dissolved Oxygen | Resolution | 0.01 mg/L |
| Dissolved Oxygen | T90 Response Time | ≤ 60s |
| Dissolved Oxygen | Temperature Compensation Accuracy | ≤ ±0.3 mg/L |
| Dissolved Oxygen | Electrode Material | Stainless steel |
| Dissolved Oxygen | Dimensions | Φ23 × 190mm |
| Dissolved Oxygen | Cable Length | Default 1.5m (customizable) |
| Dissolved Oxygen | Waterproof Rating | IP68 |
| Conductivity | Measurement Principle | Two-wire graphite electrode method |
| Conductivity | Measurement Parameters | Conductivity, Temperature |
| Conductivity | Range | Conductivity: 0 ~ 20000 μs/cm, Temperature: 0 ~ 60℃ |
| Conductivity | Accuracy | ≤ ±1% |
| Conductivity | Repeatability | ≤ ±1% |
| Conductivity | Resolution | Conductivity: 0.01 μs/cm |
| Conductivity | T90 Response Time | ≤ 15s |
| Conductivity | Temperature Compensation Accuracy | ≤ ±1% |
| Conductivity | Material | Graphite, Stainless steel |
| Conductivity | Dimensions | Φ26 × 165mm |
| Conductivity | Cable Length | Default 1.5m (customizable) |
| Conductivity | Waterproof Rating | IP68 |
| ORP | Measurement Principle | Electrochemical method |
| ORP | Measurement Parameters | ORP |
| ORP | Range | mV: -2000.0 ~ 2000.0 mV |
| ORP | Accuracy | ≤ ±0.1% F.S |
| ORP | Repeatability | ≤ ±1 mV |
| ORP | Resolution | 0.1 mV |
| ORP | Material | Plastic, Platinum |
| ORP | Dimensions | Φ12 × 155mm |
| ORP | Cable Length | Default 1m (customizable) |
| ORP | Weight | 40g |
| ORP | Waterproof Rating | IP68 |
| Ammonia Nitrogen | Measurement Principle | Ion selective method |
| Ammonia Nitrogen | Measurement Parameters | Ammonia nitrogen, pH, Temperature |
| Ammonia Nitrogen | Range | Ammonia nitrogen: 0 ~ 100 mg/L NH4-N, pH: 2 ~ 12, Temperature: 0 ~ 50℃ |
| Ammonia Nitrogen | Accuracy | Ammonia nitrogen: ±10% of measured value or ±0.5 mg/L, whichever is greater, depends on calibration; pH: ±0.1 pH |
| Ammonia Nitrogen | Resolution | Ammonia nitrogen: 0.01 mg/L, pH: 0.01 |
| Ammonia Nitrogen | Maximum Depth | 10 meters underwater |
| Ammonia Nitrogen | Material | POM |
| Ammonia Nitrogen | Dimensions | Φ54 × 273mm |
| Ammonia Nitrogen | Cable Length | Default 1.5m (customizable) |
| Ammonia Nitrogen | Protection Level | IP68 |
| Nitrate | Measurement Principle | Ion selective method |
| Nitrate | Measurement Range | 0.1-14000 ppm (or mg/L) |
| Nitrate | Ion Symbol | NO3 |
| Nitrate | Resolution | 0.001 ppm |
| Nitrate | Temperature Range | 0.0 ~ 50℃ |
| Nitrate | Slope | 56 ± 4 mV (25℃) |
| Nitrate | Housing Material | PC, PBT anti-corrosion |
| Nitrate | Connection Thread | NPT3/4, M39*1.5 |
| Nitrate | Dimensions | Φ39 * 205mm |
| TDS | Measurement Range | 0-100 g/L |
| TDS | Resolution | 0.01 g/L |
| TDS | Measurement Accuracy | ≤ ±1.5% |
| TDS | Response Time | ≤ 15s |
| TDS | Temperature Element | NTC10K |
| TDS | Temperature Range | 0 ~ 60℃ |
| TDS | Temperature Accuracy | ≤ ±0.3℃ |
| Salinity | Range | 0-160 ppt |
| Salinity | Accuracy | ±1% |
| Salinity | Resolution | 0.01 ppt |
| Salinity | Response Time | ≤ 15 s |
| Salinity | Protection Level | IP68 |
| Chloride Ion | Measurement Range | 1.8-35000 ppm |
| Chloride Ion | Resolution | 0.001 mg/L |
| Chloride Ion | Measurement Accuracy | ±5% F.S |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
pH Conductivity & Water Analysis by Infitek. Match measured parameters, range, probe compatibility and sample conditions.
Capacity of Cell: 15ml(standard); Temperature Control Range: 30-40℃. Match measured parameters, range, probe compatibility and sample conditions.
pH / Measurement Range: (-2.00-20.00) pH; ORP / Measurement Range: (-1999.9-+1999.9)mV. Match measured parameters, range, probe compatibility and sample conditions.