Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Multiparameter Bluetooth Conductivity Meter, CON-BT50-M, CON-BT50-H is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: CON-BT50-M;, CON-BT50-H;. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | CON-BT50-M; | CON-BT50-H; |
|---|---|---|
| Conductivity | Conductivity | Conductivity |
| Range | 10μS/cm to 20mS/cm | 100μS/cm to 200mS/cm |
| Resolution | 0.001, 0.01, 0.1, 1 | 0.001, 0.01, 0.1, 1 |
| Accuracy | ±0.5% F.S. | ±0.5% F.S. |
| Calibration Points | 1 to 3 points | 1 to 3 points |
| Calibration Solutions | 84µS, 1413µS, 12.88mS, 111.8mS | 84µS, 1413µS, 12.88mS, 111.8mS |
| TDS | TDS | TDS |
| Range | 0 to 20.00g/L | 0 to 200.0g/L |
| Resolution | 0.01, 0.1, 1 | 0.01, 0.1, 1 |
| Accuracy | ±1% F.S. | ±1% F.S. |
| TDS Factor | 0.01 to 1.00 (Default 0.5) | 0.01 to 1.00 (Default 0.5) |
| Salinity | Salinity | Salinity |
| Range (Practical Salinity) | 0.00 to 10.00psu | 0.00 to 42.00psu |
| Range (Natural Seawater) | 0.00 to 10.00ppt | 0.00 to 80.00ppt |
| Range (%) | 0.00 to 1.00% | 0.00 to 8.00% |
| Resolution | 0.01 | 0.01 |
| Accuracy | ±1% F.S. | ±1% F.S. |
| Resistivity | Resistivity | Resistivity |
| Range | 0.00 to 10.00MΩ | 0.00 to 1.00MΩ |
| Resolution | 0.01, 0.1, 1 | 0.01, 0.1, 1 |
| Accuracy | ±1% F.S. | ±1% F.S. |
| Conductviity Ash | Conductviity Ash | Conductviity Ash |
| Range | 0 to 100% | 0 to 100% |
| Accuracy | ±1% F.S. | ±1% F.S. |
| Measurement Modes | Refined sugar or raw sugar | Refined sugar or raw sugar |
| General Specificaions | General Specificaions | General Specificaions |
| Temperature Compensation | 0 to 100°C/32 to 212°F, automatic | 0 to 100°C/32 to 212°F, automatic |
| Temperature Coefficient | Linear (0.0 to 10.0%/°C), non-linear, USP, EP | Linear (0.0 to 10.0%/°C), non-linear, USP, EP |
| Pure Water Compensation | Yes | Yes |
| Reference Temperature | 20/25°C | 20/25°C |
| Cell Constant | K=1 | K=10 |
| Stability Criteria | Fast, standard, slow | Fast, standard, slow |
| Measurement Modes | Continuous or auto-read | Continuous or auto-read |
| Timed Interval Readings | 10, 30, 60, 300 seconds or off | 10, 30, 60, 300 seconds or off |
| Calibration Due Alarm | 1 to 99 days or off | 1 to 99 days or off |
| Data Transfer | Send to memory or printer | Send to memory or printer |
| Password Protection | 6 digits | 6 digits |
| Connectivity | Bluetooth 4.0 or later | Bluetooth 4.0 or later |
| Max Wireless Range | 10m/32.8ft | 10m/32.8ft |
| Power | 2×1.2V lithium batteries or AAA batteries | 2×1.2V lithium batteries or AAA batteries |
| Dimensions | 185(L)×40(Dia.)mm | 185(L)×40(Dia.)mm |
| Weight | 100g | 100g |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temperature / Range: 0.0~105.0°C. Match measured parameters, range, probe compatibility and sample conditions.
Temperature / Range: 0~50°C. Match measured parameters, range, probe compatibility and sample conditions.
Temperature / Range: 00-105.0°C. Match measured parameters, range, probe compatibility and sample conditions.