Skip to main content

Infitek Multi-parameter Analyzer, BEP-M500A

Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Multi-parameter Analyzer, BEP-M500A is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: BEP-M500A. Published details include Temperature / Range: -10 to 135 ºC, 14 to 275 ºF. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelBEP-M500A
ParameterspH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.)
pH / Range-2.000 to 20.000 pH
pH / Resolution0.1, 0.01, 0.001pH
pH / Accuracy±0.002 pH
pH / Calibration PointsUp to 6
pH / Standard CustomizationYes
pH / Calibration ReminderYes
pH / Standard RecognitionNIST, GB, DIN, USA, MERK, JIS buffers
pH / Slope LimitYes
mV/ORP / Range-2000.00 to 2000.00 mV
mV/ORP / Resolution0.1, 0.01 mV
mV/ORP / Accuracy±0.1 mV or ±0.03% of reading whichever is greater
mV/ORP / EH ORP ModeYes
mV/ORP / ORP Calibration Points1 custom point (relative mV)
pX / Range-2.000 to 20.000 pX
pX / Resolution0.1, 0.01, 0.001 pX
pX / Accuracy±0.002 pX
pX / Calibration PointsUp to 6
ISE / Range1E-9 to 9.999E9
ISE / Unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm
ISE / ResolutionUp to 4 significant digits
ISE / Accuracy±0.3%
ISE / Calibration PointsUp to 6
Conductivity / Range0.000 μS/cm to 2000 mS/cm
Conductivity / Resolution0.001 μS/cm minimum, various with range selection
Conductivity / Accuracy±0.5% FS
Conductivity / Reference Temperature5, 10, 15, 18, 20, 25 ºC
Conductivity / Calibration PointsUp to 5
Conductivity / Calibration ReminderYes
Conductivity / Standard Recognition10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm
Resistivity / Range5.00 Ω·cm~100.00 MΩ·cm
Resistivity / Resolution0.01 Ω·cm minimum
Resistivity / Accuracy±0.5% FS
TDS / Range0.000~1000ppt
TDS / Resolution0.001ppm minimum, changed with range
TDS / Accuracy±0.5%
Salinity / TypeNaCl
Salinity / Range0.0~80.0ppt
Salinity / Resolution0.1ppt
Salinity / Accuracy±1ppt
Temperature / Range-10 to 135 ºC, 14 to 275 ºF
Temperature / UnitºC, ºF
Temperature / Resolution0.1
Temperature / Accuracy±0.1
Measurement / Reading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Measurement / Reading PromptsReading, Stable, Locked
Measurement / Temp. CompensationATC, MTC
Data management / Data Storage1000 Groups
Data management / GLP FeaturesYes
Data management / Log ManagementYes
Inputs / pH ElectrodeBNC(Q9)
Inputs / DO with Temp. Probe4-pin aviation connector
Inputs / Conductivity with Temp. Probe5-pin aviation connector
Outputs / USBUSB 2.0 flash memory device, PC
Outputs / RS 232printer, scanner, auto-sampler
Display options / BacklightYes
Display options / Auto Shutdown1~60 min, off
Display options / IP RatingIP54
Display options / Date and TimeYes
General / ElectricityAC Adapter, 100-240V AC input, DC24V output
General / Dimensions220×195×68 mm
General / Weight950g

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category